Influence of blinding sequence of radiographs on the reproducibility and sensitivity to change of joint space width measurement in knee osteoarthritis

Authors

  • Déborah Gensburger,

    Corresponding author
    1. INSERM Research Unit 831 and Université de Lyon, Lyon, France
    • INSERM Unit 831, Pavillon F, Hôpital Edouard Herriot, 69437 Lyon Cedex 03, France
    Search for more papers by this author
    • Drs. Gensburger, Ravaud, and Chapurlat have received consultancy fees, speaking fees, and/or honoraria (less than $10,000 each) from Servier Laboratories.

  • Jean-Paul Roux,

    1. INSERM Research Unit 831 and Université de Lyon, Lyon, France
    Search for more papers by this author
  • Monique Arlot,

    1. INSERM Research Unit 831 and Université de Lyon, Lyon, France
    Search for more papers by this author
  • Elisabeth Sornay-Rendu,

    1. INSERM Research Unit 831 and Université de Lyon, Lyon, France
    Search for more papers by this author
  • Philippe Ravaud,

    1. Hôpital Hôtel-Dieu, Assistance Publique Hôpitaux de Paris, Université Paris René Descartes, and INSERM Unité 738, Paris, France
    Search for more papers by this author
    • Drs. Gensburger, Ravaud, and Chapurlat have received consultancy fees, speaking fees, and/or honoraria (less than $10,000 each) from Servier Laboratories.

  • Roland Chapurlat

    1. INSERM Research Unit 831 and Université de Lyon, Lyon, France
    Search for more papers by this author
    • Drs. Gensburger, Ravaud, and Chapurlat have received consultancy fees, speaking fees, and/or honoraria (less than $10,000 each) from Servier Laboratories.


Abstract

Objective

To investigate whether knowledge of the sequence of radiographs impacts inter- and intraobserver reproducibility and sensitivity to change for measuring joint space width (JSW) in patients with knee osteoarthritis (OA).

Methods

A cohort of 70 postmenopausal women with radiologic knee OA was assessed through the measurement of knee radiographs acquired in the semiflexed posteroanterior view, using a positioning frame and fluoroscopy, at baseline and 48 months later. Paired readings of radiographs were made using landmarks at baseline by 2 independent observers unblinded to sequence and blinded to sequence. Intra- and interobserver reproducibility was assessed on JSW measurements at baseline and 4 years later and on the longitudinal difference (joint space narrowing [JSN]), using intraclass correlation coefficient (ICC) and Bland and Altman methods. The sensitivity to change was assessed through standardized response means (SRMs).

Results

For JSW and JSN and with both methods, ICCs were high for the intra- and interobserver reproducibility (0.90–0.99 for JSW and 0.77–0.89 for JSN). For the Bland-Altman method, the mean difference was close to 0, with no bias for both observers and methods. The SRMs ranged from 0.38 to 0.48. All of the results were numerically in favor of measuring with knowledge of time sequence, but without a statistically significant difference between the methods.

Conclusion

Intra- and interobserver reproducibility was high with or without blinding of the radiograph sequence. Reading with knowledge of time sequence using baseline landmarks tended to improve sensitivity. Therefore, in longitudinal studies of OA radiographs can be read unblinded to sequence.