Discrimination and Selective Enhancement of Signals in the MALDI Mass Spectrum of a Protein by Combining a Matrix-Based Label for Lysine Residues with a Neutral Matrix

Authors

  • David Lascoux,

    1. Protein Mass Spectrometry Laboratory, Institut de Biologie Structurale, CEA, CNRS, UJF, UMR 5075, 41 rue Jules Horowitz, 38027 Grenoble Cedex 1, France, Fax: (+33) 4-3878-5494
    Search for more papers by this author
  • David Paramelle,

    1. Institut des Biomolécules Max Mousseron (IBMM), UMR5247 CNRS, Universités Montpellier 1 et 2, 15 avenue Charles Flahault, 34000 Montpellier, France, Fax: (+33) 4-6754-8654
    Search for more papers by this author
  • Gilles Subra Dr.,

    1. Institut des Biomolécules Max Mousseron (IBMM), UMR5247 CNRS, Universités Montpellier 1 et 2, 15 avenue Charles Flahault, 34000 Montpellier, France, Fax: (+33) 4-6754-8654
    Search for more papers by this author
  • Michaël Heymann,

    1. Institut de Biologie et Chimie des Protéines, Laboratoire de Bioinformatique et RMN structurales Pole BioInformatique Lyonnais, UMR 5086 CNRS, Université Lyon 1, 7 passage du Vercors, 69367 Lyon, France
    Search for more papers by this author
  • Christophe Geourjon Dr.,

    1. Institut de Biologie et Chimie des Protéines, Laboratoire de Bioinformatique et RMN structurales Pole BioInformatique Lyonnais, UMR 5086 CNRS, Université Lyon 1, 7 passage du Vercors, 69367 Lyon, France
    Search for more papers by this author
  • Jean Martinez Prof.,

    1. Institut des Biomolécules Max Mousseron (IBMM), UMR5247 CNRS, Universités Montpellier 1 et 2, 15 avenue Charles Flahault, 34000 Montpellier, France, Fax: (+33) 4-6754-8654
    Search for more papers by this author
    • These authors contributed equally to this research.

  • Eric Forest Dr.

    1. Protein Mass Spectrometry Laboratory, Institut de Biologie Structurale, CEA, CNRS, UJF, UMR 5075, 41 rue Jules Horowitz, 38027 Grenoble Cedex 1, France, Fax: (+33) 4-3878-5494
    Search for more papers by this author
    • These authors contributed equally to this research.


Abstract

original image

Unterscheidung gelungen: Der N-Hydroxysuccinimidester von HCCA (α-Cyan-4-hydroxyzimtsäure) wurde als Markierungsmittel genutzt, um das MALDI-MS-Signal bestimmter, gering konzentrierter Peptide in einer aus Cytochrom c erhaltenen proteolytischen Mischung relativ zu den Signalen anderer Peptide zu verstärken. Der erwünschte Effekt trat nur bei der neutralen MALDI-Matrix HCCE (dem Methylester von HCCA) auf (siehe Massenspektren).

Ancillary