Article
Biological effects of a 765-kV transmission line: Exposures and thresholds in honeybee colonies
Article first published online: 19 OCT 2005
DOI: 10.1002/bem.2250020404
Copyright © 1981 Wiley-Liss, Inc., A Wiley Company
Additional Information
How to Cite
Greenberg, B., Bindokas, V. P. and Gauger, J. R. (1981), Biological effects of a 765-kV transmission line: Exposures and thresholds in honeybee colonies. Bioelectromagnetics, 2: 315–328. doi: 10.1002/bem.2250020404
Publication History
- Issue published online: 19 OCT 2005
- Article first published online: 19 OCT 2005
- Manuscript Revised: 31 AUG 1981
- Manuscript Received: 5 JUN 1981
Funded by
- Electric Power Research Institute, Palo Alto, California. Grant Number: RP934-1
- IIT Research Institute (IITRI). Grant Number: RP934-2
- Abstract
- References
- Cited By
Keywords:
- electric fields;
- 60 Hz;
- honeybees;
- transmission lines
Abstract
Honeybee colonies exposed under a 765-kV, 60-Hz transmission line at 7 kV/m show the following sequence of effects: 1) increased motor activity with transient increase in hive temperature; 2) abnormal propolization; 3) impaired hive weight gain; 4) queen loss and abnormal production of queen cells; 5) decreased sealed brood; and 6) poor winter survival. When colonies were exposed at 5 different E fields (7, 5.5, 4.1, 1.8, and 0.65–0.85 kV/m) at incremental distances from the line, different thresholds for biologic effects were obtained. Hive net weights showed significant dose-related lags at the following exposures: 7 kV/m, one week; 5.5 kV/m, 2 weeks; and 4.1 kV/m, 11 weeks. The two lowest exposure groups had normal weight after 25 weeks. Abnormal propolization of hive entrances did not occur below 4.1 kV/m. Queen loss occurred in 6 of 7 colonies at 7 kV/m and 1 of 7 at 5.5 kV/m, but not below. Foraging rates were significantly lower only at 7 and 5.5 kV/m. Hive weight impairment and abnormal propolization occur at lower E-field intensity than other effects and limit the “biological effects corridor” of the transmission line to approximately 23 m beyond a ground line projection of each outer phase wire. Intrahive E fields of 15–100 kV/m were measured with a displacement current sensor. Step-potential-induced currents up to 0.5 μA were measured in an electrically equivalent bee model placed on the honeycomb in a hive exposed at 7 kV/m. At 1.8 kV/m body currents were a few nanoamperes, or two orders of magnitude lower, and these colonies showed no effects. E-field versus electric shock mechanisms are discussed.