Formulation and Engineering of Biomaterials
Target concentration dependence of DNA melting temperature on oligonucleotide microarrays
Article first published online: 24 JAN 2012
DOI: 10.1002/btpr.1505
Copyright © 2012 American Institute of Chemical Engineers (AIChE)
Additional Information
How to Cite
Ozel, A. B., Srivannavit, O., Rouillard, J.-M. and Gulari, E. (2012), Target concentration dependence of DNA melting temperature on oligonucleotide microarrays. Biotechnol Progress, 28: 556–566. doi: 10.1002/btpr.1505
Publication History
- Issue published online: 10 APR 2012
- Article first published online: 24 JAN 2012
- Accepted manuscript online: 14 DEC 2011 01:25PM EST
- Manuscript Revised: 8 NOV 2011
- Manuscript Received: 20 AUG 2011
Funded by
- National Institute of Health. Grant Numbers: 1R41HG004103-01, 1R21HG003725-01, 1R01GM068564-01
Keywords:
- DNA melting temperature;
- oligonucleotide microarray;
- target concentration;
- DNA hybridization thermodynamics
Abstract
The design of microarrays is currently based on studies focusing on DNA hybridization reaction in bulk solution. However, the presence of a surface to which the probe strand is attached can make the solution-based approximations invalid, resulting in sub-optimum hybridization conditions. To determine the effect of surfaces on DNA duplex formation, the authors studied the dependence of DNA melting temperature (Tm) on target concentration. An automated system was developed to capture the melting profiles of a 25-mer perfect-match probe–target pair initially hybridized at 23°C. Target concentrations ranged from 0.0165 to 15 nM with different probe amounts (0.03–0.82 pmol on a surface area of 1018 Å2), a constant probe density (5 × 1012 molecules/cm2) and spacer length (15 dT). The authors found that Tm for duplexes anchored to a surface is lower than in-solution, and this difference increases with increasing target concentration. In a representative set, a target concentration increase from 0.5 to 15 nM with 0.82 pmol of probe on the surface resulted in a Tm decrease of 6°C when compared with a 4°C increase in solution. At very low target concentrations, a multi-melting process was observed in low temperature domains of the curves. This was attributed to the presence of truncated or mismatch probes. © 2012 American Institute of Chemical Engineers Biotechnol. Prog., 2012