Process Sensing and Control
Raman spectroscopy and chemometrics for on-line control of glucose fermentation by Saccharomyces cerevisiae
Article first published online: 21 SEP 2012
DOI: 10.1002/btpr.1615
Copyright © 2012 American Institute of Chemical Engineers (AIChE)
Additional Information
How to Cite
Ávila, T. C., Poppi, R. J., Lunardi, I., Tizei, P. A. G. and Pereira, G. A. G. (2012), Raman spectroscopy and chemometrics for on-line control of glucose fermentation by Saccharomyces cerevisiae. Biotechnol Progress, 28: 1598–1604. doi: 10.1002/btpr.1615
Publication History
- Issue published online: 4 DEC 2012
- Article first published online: 21 SEP 2012
- Accepted manuscript online: 13 AUG 2012 04:23AM EST
- Manuscript Revised: 3 AUG 2012
- Manuscript Received: 4 JUN 2012
Funded by
- CAPES
- CNPq
- FAPESP
- Abstract
- Article
- References
- Cited By
Keywords:
- on-line monitoring;
- Raman spectroscopy;
- partial least squares;
- multiway principal component analysis;
- multivariate control charts
Abstract
This work presents the use of Raman spectroscopy and chemometrics for on-line control of the fermentation process of glucose by Saccharomyces cerevisiae. In a first approach, an on-line determination of glucose, ethanol, glycerol, and cells was accomplished using multivariate calibration based on partial least squares (PLS). The PLS models presented values of root mean square error of prediction (RMSEP) of 0.53, 0.25, and 0.02% for glucose, ethanol and glycerol, respectively, and RMSEP of 1.02 g L−1 for cells. In a second approach, multivariate control charts based on multiway principal component analysis (MPCA) were developed for detection of fermentation fault-batch. Two multivariate control charts were developed, based on the squared prediction error (Q) and Hotelling's T2. The use of the Q control chart in on-line monitoring was efficient for detection of the faults caused by temperature, type of substrate and contamination, but the T2 control chart was not able to monitor these faults. On-line monitoring by Raman spectroscopy in conjunction with chemometric procedures allows control of the fermentative process with advantages in relation to reference methods, which require pretreatment, manipulation of samples and are time consuming. Also, the use of multivariate control charts made possible the detection of faults in a simple way, based only on the spectra of the system. © 2012 American Institute of Chemical Engineers Biotechnol. Prog., 2012

1520-6033/asset/BTPR_left.gif?v=1&s=a5be2ff5a0fe6ccdaad74a6d128c142e5f71a8da)
1520-6033/asset/BTPR_right.gif?v=1&s=992d113a3e61fc9d3571812359165df86cf830e4)
