SEARCH

SEARCH BY CITATION

Keywords:

  • tribo-charging;
  • fluidization;
  • charge generation;
  • monitoring;
  • induction probes;
  • attractor comparison method

Abstract

The electrostatic charge distribution in a lab-scale 2-D fluidized bed of 900 µm glass beads was determined using arrays of induction probes, and the influence of relative humidity and superficial gas velocity was examined. The bubble presence, relative humidity, and superficial gas velocity were found to influence charge separation. Bipolar charging was observed; the net charge build-up was found to be negligible. Moreover, the system was monitored by applying the attractor comparison method to the electrostatic charge signals from an induction probe. It was concluded that this approach can indeed be used to monitor changes in the electrostatic behaviour.

La distribution de charge électrostatique dans un lit fluidisé en 2-D à l'échelle de laboratoire garni de billes de verre de 900 µm, a été déterminée à l'aide d'un ensemble de sondes d'induction, et l'influence de l'humidité relative et de la vitesse de gaz superficielle a été examinée. On a trouvé que la présence de bulles, l'humidité relative et la vitesse de gaz superficielle influençaient la séparation de charge. Une charge bipolaire a été observée; l'accroissement de charge nette s'avère négligeable. En outre, on a effectué le suivi du système en appliquant la méthode de comparaison des attracteurs aux signaux de charge électrostatique à partir d'une sonde d'induction. On a conclu que cette approche peut effectivement être utilisée pour effectuer le suivi des changements dans le comportement électrostatique.