This article presents the results obtained from analysing the impacts of bed media, static bed height, and the water-to-air mass flow ratios on the mass transfer coefficient and Colburn factor. The experimental data were compared with the correlations for mass transfer and the analogy between heat and mass transfer in conical spouted beds described earlier in literature. Moreover, the aim of the article is to present some new correlations of dimensionless groups for description of mass transfer and analogy of heat and mass transfer in sprayed spouted beds, which were developed by the authors.

Cet exposé présente les résultats obtenus suite à l'analyse de l'impact du médium et de la hauteur statique du lit, des rapports d'écoulement de la masse eau-air sur le coefficient de transfert de masse et le facteur de Colburn. Les données expérimentales ont été comparées aux corrélations pour le transfert de masse et à l'analogie entre le transfert de chaleur et de masse dans des lits jaillissants coniques décrits plus tôt dans la documentation. En outre, le but de l'article est de présenter quelques nouvelles corrélations de groupes adimensionnels, développées par les auteurs, en vue de décrire le transfert de masse et l'analogie du transfert de chaleur et de masse dans les lits jaillissants pulvérisés.