Abstract

The pressure drop of aqueous model nylon fibre suspensions was determined in a vertical 2-in. copper tube in the turbulent range as a function of velocity, fibre length-to-diameter ratio (L/D) and concentration. Fibre diameters ranged from 20.2 to 51.6 microns and length from 0.52 to 1.21 mm. A marked depression below the value for the pressure drop of water was observed at high L/D's and its magnitude increased with the solids concentration. For low L/D values the depression was almost negligible. An explanation is advanced for the depression in pressure drop based on alterations in the turbulence characteristics in the presence of fibres.

On a déterminé la perte de charge de suspensions aqueuses de fibres de nylon, en écoulement turbulent, dans un tube de cuivre vertical (diam. 2″) en fonction de la vitesse, de la concentration et du rapport longueur/diamètre (L/D) de la fibre. Les fibres varient de 20.2 à 51.6 microns en diamètre et 0.52 à 1.21 mm en longueur. On observe une diminution marquée de la perte de charge, comparativement à celle obtenue avec l'eau, pour des valeurs de (L/D) élevées et cette diminution augmente avec la concentration des fibres. Pour des faibles valeurs (L/D) cette diminution est presque négligeable. On explique ce phénomène en fonction des modifications que subissent les courants de turbulence en présence de fibres.