Get access

Heat transfer studies in a climbing film evaporator: Part I. Heat transfer from condensing steam to boiling water

Authors


Abstract

Hard water was concentrated using steam heating in a single tube climbing film evaporator, of length 9 ft. and external diameter 1 inch.

The heat flux Q/A in BTU/hr. sq. ft. was found to be related to the feed rate of the water M lb./hr. and its temperature Ti °F by the equation

Q/A = ψ M0.6 + 90.3 (TbTi) Cp

where ψ is a graphically read function of the temperature difference driving force between the condensing steam and the boiling water. The data fit the above equation with a standard deviation of 2.6%.

The empirically derived equation for heat flux was also found to represent the data for other aqueous solutions with reasonable accuracy.

Abstract

Le phénomène de film ascendant est utilisé pour concentrer une eau dure dans un évaporateur qui consiste d'un tube, chauffé à la vapeur, dont le diamétre est 1 pouce et la longueur 9 pieds.

Le flux de chaleur Q/A en Btu/hre × pi2 est fonction du taux d'alinientation de l'eau, M lbs/hre, et de sa température en °F soit:

Q/A = ψ M0.6 + 90.3 (TbTi) Cp

où ψ = fonction du potentiel de température entre la vapeur qui se condense et l'eau à l'ébullition. La relation donnée présente une déviation standard de 2.6%.

L'équation empirique proposée pour le flux de chaleur représente bien, de plus, les autres données disponibles pour des solutions aqueuses.

Get access to the full text of this article

Ancillary