SEARCH

SEARCH BY CITATION

Abstract

The Θ-method and block-relaxation method of solving The non-linear set of algebraic equations which describe the leady-state behavior of standard distillation columns are compared.

The results from the mathematical models are compared with actual plant performance of a depropanizer, debutanizer, de-ethanizer, and ethane-ethylene splitter. Column section efficiencies are tabulated. A parametric study of the variation of feed condition, reflux condition and flow, and feed tray location was made on these columns and the responses of the key component concentrations have been mapped.

Such a study permits improvement of current plant operation. Its use for design of more efficient columns and arranangements is indicated.

On compare la méthode-Θ avec celle de la détente des blocs pour résoudre la série non-linéaire d'équations algébriques, oú I'on décrit le rendement constant des colonnes normales à distillation.

On compare les résultats provenant de modèles mathématiques avec le rendement réel d'usines pour éliminer le propane, le butane et l'éthane et séparer l'éthane de l'éthylène. Les rendements des sections de colonnes apparaissent sur un tableau. On a fait sur ces colonnes une étude paramétrique de la variation des conditions d'alimentation, du flux et du reflux ainsi que l'endroit oú se trouve le plateau d'alimentation, et transposé sur carte les réponses des concentrations des principaux éléments.

L'étude précitée permet d'améliorer le fonctionnement normal de l'usine et son emploi est indiqué pour la conception de colonnes plus efficaces et autres arrangements.