Get access
Advertisement

Radial gas dispersion in a column packed with screen cylinders

Authors


Abstract

Gaseous eddy diffusivity measurements were made by a point injection technique in a 6.5-in. column packed with open-end screen cylinders varying in size from 3/8-in. to 1 1/2-in. diameter, and made from wire cloth varying from 4 to 28 mesh/in. Oxygen was used as the tracer gas. Only packings made from 4 to 10 mesh/in. produced concentration profiles which were symmetric. The latter data show that turbulent diffusivity increases linearly with gas flow rate, but decreases with decreasing mesh opening and wire diameter. A correlation is presented for turbulent diffusivities as a function of the Reynolds number, dmuρ/m̈, and the ratio dw/dm.

Abstract

On a mesuré la diffusivité ďun tourbillon gazeux au moyen ďune méthode ďinjection en un point dans une colonne de 6.5 pouces, garnie de cylindres-cribles en toile métallique de 4 à 28 mailles au pouce, dont les extrémités étaient ouvertes et dont le diamètre variat entre 3/8 pouce et 1 1/2 pied; on a utilisé ľoxygène comme gaz-indicateur. Seules les garnitures en toile métallique de 4 à 10 mailles au pouce ont produit des profils de concentration qui étaient symétriques, ce qui indique que la diffusivité du tourbillon gazeux augmente en ligne droite avec la vitesse ďécoulement du gaz, mais décroǐt avec les mailles et le diamètre de la toile métallique. On présente une corrélation pour les diffusivités turbulentes en fonction du nombre de Reynolds dmuρ/m̈, et du rapport dw/dm.

Get access to the full text of this article

Ancillary