Direct contact condensation of steam in a packed column with immiscible heat transfer agents

Authors


Abstract

Steam was condensed in a four inch inside diameter column packed with three-eighth inch ceramic Raschig rings using Aroclor 1242 and 1248 as co-current heat transfer agents. The packing heights used for condensing the steam were estimated from the liquid temperature profile in the column. From this value and the liquid temperatures the height of a transfer unit for condensation (HCU) was calculated. The HCU was found to be strongly affected by the mean heat transfer medium viscosity and by the flow rate of the liquid. Two empirical equations have been developed to describe the results of this study. Both are of the form

equation image

Abstract

On a condensé de la vapeur d'eau dans une colonne de quatre pouceg de diamètre intérieur, laquelle était garnie d'anneaux céramiques de Raschig de 3/8 de pouce, en utilisant les produits Aroclor 1242 et 1248 comme agents con-courants de transfert de la chaleur. On a évalué les hauteurs de la garniture servant à la condensation de la vapeur d'eau à partir du profil de température du liquide dans la colonne, puis calculé la hauteur d'une unite de transfert pour la condensation (HCU) à me'me cette valeur et les températures du liquide. On a constaté que la valeur HCU trouvée était fortement affectée par la viscosité moyenne du milieu servant au transfert de la chaleur et par la vitesse d'écoulement du liquide. On a mis au point deux équations empiriques pour décrire les résultats de cette étude, lesquelles sont de la forme suivante:

equation image

Ancillary