SEARCH

SEARCH BY CITATION

Abstract

In this work a resistivity probe for local property measurements, developed originally(1, 2, 3) for (non-wetting) mercury-nitrogen flows, was adapted to a broader class of gas-liquid flows, such as air-water. To compensate for the non-negligible dry-out time of the probe in aqueous systems, a trigger circuit was installed to sense bubble arrival rapidly. Another problem which was solved was the greater tendency for bubbles in water, as compared to mercury, to deflect away from the probe. The probe signal is an instantaneous record of the arrival and departure of bubbles at any point in the flow, and hence is well-adapted to auto and cross-correlation measurements, as well as distribution function studies.

Pour mesurer des propriétés locales, on a adapté dans le travail actuel à une classe plus étendue d'écoulements de gaz et de liquides (e. g. air et eau) une sonde de résistivité qu'on avail originalement(1, 2, 3) mise au point pour des écoulements (non-mouillants) de mercure et d'azote. Pour obvier au séchage non-négligeable de la sonde dans des systèmes aqueux, on a installé un circuit à détente pour déceler rapidement l'arrivée des bulles. Un autre problème qu'on a résolu a été celui que présente la tendance des bulles à dévier davantage de la sonde dans l'eau que dans le mercure. Le signal de la sonde indique instantanément l'arrivée et le départ des bulles en n'importe quel point de l'écoulement et il est, par conséquent, bien adapté aux mesures d'auto-corrélation ainsi qu'aux études de la fonction de distribution.