Abstract

An analytical and experimental investigation was made of the frequency response of both the shell and tube fluid outlet temperatures of a six foot concentric tube exchanger to disturbances in either flow rate. The fluid Reynolds and Prandtl numbers were varied from 4,000 to 20,000 and 3 to 40 respectively.

The effect of increasing either the tube fluid Reynolds or Prandtl number, for both shell and tube flow disturbances, was to increase the attenuation and phase shift of the tube outlet temperature and decrease it for the shell outlet temperature.

The “resonance effect”, was observed experimentally.

On a fait une étude analytique et expérimentale de la fréquence de la réponse des températures, à la sortie d'un fluide des tubes extérieur et intérieur (en utilisant un échangeur à tubes concentriques de six pieds), aux perturbations dans l'un ou l'autre débit. On a fait varier respectivement les nombres de Reynolds et de Prandtl du fluide de 4,000 à 20,000 et de 3 à 40. L'effet produit en augmentant soit le nombre de Reynolds, soit celui de Prandtl, dans le cas des perturbations dans l'écoulement pour les tubes extérieur et intérieur, a été d'accroǐtre l'atténuation et le changement de phase de la température à la sortie du tube intérieur et de les diminuer à la sortie du tube extérieur. On a observé expérimentalement “l'effet de résonance”.