SEARCH

SEARCH BY CITATION

Abstract

An apparatus for investigating pulsed turbulent liquid flow in a 2 in. diameter, 80 ft. pipeline is described. The pulsation unit was powered by compressed air with a consumption of up to 2.7 std. cu.ft./min. at 35 lb/in2 gauge. The pressure drop for water flowing at mean velocities of 7.66 to 12.28 ft./sec. has been measured, both for steady flow and for pulsed flow, at frequencies between 0.48 and 0.82 Hz. The experimentally measured pressure versus time curves for pulsed flow can be matched fairly closely by a solution of Euler's equation employing the friction factors measured under steady flow conditions.

On décrit un appareil pour étudier un courant liquide turbulent et pulsatoire dans un pipeline de 80 pieds de longueur et 2 pouces de diamètre. On a actionné le dispositif de pulsation avec de l'air comprimé à raison de 2.7 std. pieds cubes à la minute à une pression de 35 livres au pouce carré. On a mesuré la chute de pression de l'eau qui coule à des vélocités moyennes de 7.66 à 12.28 pieds à la seconde et ce dans les cas d'un courant stable et d'un courant pulsatoire et à des fréquences variant entre 0.48 et 0.82 Hz. Les graphiques reproduisant les mesures expérimentales de la pression vs le temps, dans le cas d'un écoulement pulsatoire, s'harmonisent assez bien avec la solution d'une équation d'Euler où l'on emploie les facteurs de frottement mesurés dans des conditions correspondant à celles d'un écoulement stable.