The effect of liquid maldistribution on the performance of a packed tower absorber

Authors


Abstract

A study of the effect of liquid maldistribution on the performance of a gas absorber is reported. The experimental work was carried out using the carbon dioxide-water system in a simulated packed column consisting of an ordered array of spheres. This device has been shown to closely approximate the behaviour of an actual column and permits the artificial manipulation of the liquid distribution. The results indicate that maldistribution causes only a small decrease in the mass transfer coefficient at low liquid flow rates, and has almost no effect at higher flows. A proposed iterative procedure for calculating the effect is presented.

Abstract

On préente les résultats d'une étude de l'effet d'une mauvaise distribution d'un liquide sur le rendement d'un absorbeur de gaz. On a fait le travail expérimental, en employant le système anhydride carbonique-eau, dans une colonne simulée garnie et formée de sphères disposées en rangées. On a constaté que le dit dispositif reproduisait très approximativement le comportement d'une colonne normale et permettait de manipuler artificiellement la distribution du liquide. Les résultats ont indiqué que la mauvaise distribution du liquide ne produisait qu'une faible diminution du coefficient de transfert de masse, lorsque les débits du liquide étaient faibles, et qu'il était presque sans effet lorsque les écoulements étaient élevés. On présente une méthode itérative qu'on propose pour calculer l'effet en question.

Ancillary