Heat transfer from a horizontal tube to a fluidized bed in the presence of unheated tubes

Authors


Abstract

An experimental study of heat transfer from a horizontal tube to a fluidized bed was carried out in the presence of nearby unheated tubes. The effect of the number of tubes, their size, configuration, and the type of fluidized materials was studied. Certain configurations caused as much as a 56% reduction in heat transfer over the most favorable case. The top of the tube was covered by stagnant solids, the bottom partially by a gas film, and the sides by a small region of vigorously agitated solids. Most of the heat transfer occurred in the side region. An overall heat transfer coefficient of 35 Btu/hr-ft2-°F. was found at the best conditions.

Abstract

On a fait une étude expérimentale de la transmission de la chaleur d'un tube horizontal à un lit fluidisé, en présence de tubes non chauffés dans le voisinage. On a étudié l'influence du nombre, des dimensions et de la configuration des tubes ainsi que du genre de produit fluidisé. Certaines configurations ont produit une diminution de la transmission de la chaleur allant jusqu'à 55% eu comparaison avec le cas optimal. La partie supérieure du tube était converte de matières solides stagnantes, tandis que sa partie supérieure était enduite d'une pellicule gazeuse et que ses co'tés étaient recouverts, sur une faible surface, de matières solides soumises à une forte agitation. La majeure partie du transfert de la chaleur s'est faite sur les co'tés du tube. On a trouvé, dans les conditions optimales, un coefficient de transmission globale de la chaleur de 35 Btu/heure/pied carré-°F.