SEARCH

SEARCH BY CITATION

Abstract

The analysis of the dynamic behavior of a continuous stirred tank reactor with a fluorescent tracer has indicated that the short-circuit of a fraction of the liquid feed constitutes the only non-ideality in this case. There is no dead space or piston flow in the reactor when the density difference is zero.

The variation of the transfer function time constants was also studied as a first approximation, in a reactor with a density difference between the liquid feed and the reactor contents. This had led to the determination of an ideality criterion which includes the main causes of the non-ideal mixing. The fluorescent tracer technique has permitted the isolation of the effects of physical parameters on the degree of short-circuit from the effects on other causes of non-ideal mixing.

l'analyse du compoitement dynamique d'un réservoir agité en système continu à l'aide d'un traceur fluorescent a permis de déterminer que la seule cause de non-idéalité dans ce cas était le court-circuit d'une certaine fraction de l'alimentation vers la sortie. Il n'existe pas de zone stagnante ou d'écoulement frontal lorsque la différence de densité entre les liquides est nulle.

l'étude de la variation des constantes de temps de la fonction de transfert, appliquée en première approximation à un réacteur soumis à une différence de densité, a conduit à la détermination d'un critère d'idéalité tenant compte des principals causes de la non-idéalité de l'agitation. L'utilisation du traceur fluorescent a permis d'isoler l'influence des paramètres physiques sur la variation du court-circuit.