SEARCH

SEARCH BY CITATION

Abstract

The system of design equations recently proposed by Treybal for adiabatic packed absorbers has been tested experimentally for ammonia absorption. Examination of temperature profiles and solute recoveries measured in a 6 in. packed column indicated effective interfacial areas for non-isothermal absorption to be larger than those found by Shulman for isothermal absorption. A modification of Shulman's interfacial area relationship, giving good agreement between measured and predicted recoveries and temperature profiles, is proposed. A convenient algorithm for computer solution of the design equations is described.

On a soumis à une vérification expérimentale, dans le cas de l'absorption de l'ammoniaque, le système d'équation d'étude que Treybal a proposé récemment pour les absorbeurs adiabatiques et garnis. L'examen des profils de température et de la récupération de la substance dissoute, qu'on a mesurée dans une colonne garnie de 6 pouces, ont indiqué que les régions interfaciales où il se faisait une absorption non-isothennique étaient de dimensions plus considérables que celles que Shulman avait tronvées dans le cas d'absorption isothermique. On propose une modification de la relation de Shulman relativement aux surfaces interfaciales, laquelle fournit une bonne concordance entre les mesures et les prévisions des profils de température et de la récupération de substances dissoutes. On décrit un algorithme satisfaisant pour la solution au moyen de calculatrice des équations d'étude.