Common practice for design of biological wastewater treatment systems involves evaluation of certain fixed structure systems at several alternative conditions. This study considered optimization of both the structure and the design of the system using the structural parameter system synthesis technique. The system was composed of a trickling filter, an activated sludge aeration vessel, and a secondary clarifier. Results of optimal synthesis indicated that the activated sludge system was the most cost effective system for the specific set of process parameters employed. The same conclusion was reached by optimizing several systems with different structures.

La pratique courante, dans le cas de la conception des systèmes pour le traitement biologique des eaux usagées, comprend l'évaluation de certains systèmes à structure fixe dans plusieurs alternatives. Dans le travail présent, on a étudié l'optimisation de la structure et de la conception du système en employant la méthode de synthèse d'un système à paramètres structuraux. Le système comprenait tin filtre à dégouttement, un récipient pour l'aération de la boue activée et un clarificateur secondaire. Les résultats d'une synthèse optimale ont indiqué que le système à boue activée était le plus efficace au point de vue du cou't, dans le cas des paramètres spécifiques qu'on a employés. On en est venu à la me'me conclusion en optimisant plusieurs systèmes de structures différentes.