Pressure drop, bed expansion and liquid holdup in a three phase spouted bed contactor

Authors


Abstract

Data on the pressure drop, bed expansion and liquid holdup in a three phase spouted bed contactor with an initial bed height of 243 mm. were obtained as a function of the gas and liquid flowrate. Polyethylene spheres 10 mm. in diameter with a density of 320 kg/m3 were spouted in a 194 mm. column using a 30 mm. nozzle.

The spouted bed contactor with gas and liquid mass flow-rates of 2.18 and 1.88 kg/m2 sec, respectively had similar pressure drop per unit area of particle surface, total liquid holdup per unit volume of operating bed, and “active” holdup, as a fluidized contactor.

Abstract

On a obtenu, en fonction des débits de gaz et de liquide, des données sur la chute de pression, l'expansion du lit et la rétention du liquide dans un contacteur à trois phases à base de lit fluidisé avec giclage (spouted bed); la hauteur initiale du lit était de 243 millimètres. On a giclé des sphères de 10 millimètres de diamètre et de 320 kilogrammes par mètre cube de densité dans une colonne de 194 millimètres, en utilisant un ajustage de 30 millimètres.

Le contacteur à base de lit à giclage indiquait, pour des débits respectifs de gaz et de liquide de 2.18 et 1.88 kg/mètre2/seconde, une chute de pression par unité de surface des particules, une rétention totale du liquide par unité de volume et une rétention “active” qui étaient semblables à celles d'un contacteur à base de lit fluidisé ordinaire.