Elimination d'anhydride sulfureux par réaction sur l'oxyde de cuivre en couche fluidisée

Authors


Abstract

Reaction between cupric oxide, oxygen, and sulphur dioxide has been studied in a fluidized bed reactor continuously fed with solid reactant. The effect of bed temperature, solid flow rate, gas flow rate and the hight at minimum fluidization conditions has been investigated.

Experimental conversions are between 20 to 60%.

Olcutt and Davidson's fluidized bed reactor model slightly modified for our particular reactor has been compared with experimental data. The assumption of plug flow of gas in the dense phase is good for the height of 5 cm, on the contrary, the assumption of perfect mixing of gas in the dense phase is better for the deepest bed.

Abstract

La réction entre l'oxyde de cuivre, l'oxygène et l'anhydride sulfureux a été éudiée dans un réacteur en lit fluidisé fonctionnant en continu. L'influence de la température, du débit de gaz, du débit de solide, de la hauteur au minimum de fluidisation est explicitée.

Les conversions expérimentales sont comprises entre 20 et 60%.

La modèle de Orcutt et Davidson, adapté à notre cas particulier, a été comparé à nos résultats expérimentaux. L'hypothèse de l'écoulement piston du gaz dans la phase dense convient pour la hauteur de 5 cm, par contre, l'hypothèse du mélange parfait convient mieux pour les hauteurs plus importantes.

Ancillary