Abstract

Measurement of response curves to an imperfect pulse signal were carried out in a liquid flowing cocurrently with a gas at two positions in a packed bed. Three types of ceramic packing were investigated, viz. spheres, solid cylinders and Raschig rings, all of nominal size 6 mm. The liquids used were water and a corn sugar solution of viscosity 9.13 mPa·s. The curves were analyzed by means of two models: the axially dispersed plug flow model and the Markov chain model; the latter was solved for this purpose. Empirical correlations for the model parameters were obtained.

On a mesuré les courbes de réponses à un signal d'impulsion imparfait dans un liquide qui s'écoule à co-courant avec un gaz, en deux points dans un lit garni. On a étudié trois types de garnissage en céramique, à savoir des sphéres, des cylindres solides et des anneaux Raschig, qui avaient tous la měme dimension nominale (6 millimètres). On a employé comme liquides l'eau et une solution de sucre de maïs dont la viscosité était 9.13 mPa·s. On a analysé ces courbes au moyen de deux modèles: un modèle d'écoulement piston avec dispersion axiale, et un modèle à chaǐne de Markov; on a établi le second modèle dans ce but. On a obtenu des corrélations empiriques pour les paramètres des modèles.