Development of a monitoring system for Ash deposits on boiler tube surfaces

Authors


Abstract

The etfect of ash deposits on the output of heat flux meters installed on the water wall tubes in pulverized coal fired utility boilers is studied. The objective is to use commercially available heat flux meters as the sensing devices for detecting and monitoring the growth of ash deposits. Reliable performance is shown and an attractive method is described for processing the heat flux meter output into a signal related to the ash deposit only and independent of variation of boiler load and firing conditions in the combustion chamber. Patents are pending for this Monitoring System.

Abstract

On a étudié l'effet de dépôts de cendres sur les indications de compteurs de flux de chaleur, installés sur la paroi des tubes en contact avec l'eau, dans des chaudiéres de service chauffées au charbon pulvérisé. Le but de cette étude était d'employer des compteurs de flux de chaleur commerciaux comme dispositifs de détection et de mesure de la croissance des dépôts de cendres. On a constaté que la mesure était reproductible et l'on décrit une méthode intéressante pour transformer l'indication du compteur de flux de chaleur en signal qui ne dépend que du dépôt de cendres et qui est indépendant de la variation de la charge de la chaudiére et des conditions de chauffage dans la chambre de combustion. Une demande de brevets a été déposée.

Ancillary