Size of bubbles and liquid circulation in a bubble column with a draught tube and sieve plate

Authors


Abstract

The size distribution of bubbles and the liquid circulation in a bubble column with a draught tube and sieve plate were studied experimentally. The size of bubbles is well correlated with the previous result of the authors; the size distribution data are fitted reasonably well by a logarithmic normal probability distribution. Gas holdup in the draught tube and annulus and pressure drop were measured and correlations for these parameters are obtained.

An energy balance is used to predict liquid circulating velocity using gas holdup and pressure drop correlations. Reasonable agreement is found between the calculated and measured circulating velocity.

Abstract

On a étudié de manière expérimentale la distribution de taille des bulles et la circulation du liquide dans une colonne à bulles munie d'un tube d'aspiration et d'un plateau perforé. La taille des bulles est corrélée de manière satisfaisante avec les résultats précédents des auteurs; les données de la répartition de la taille suivent raisonnablement bien la courbe logarithmique normale de distribution des probabilités. La rétention des gaz dans le tube d'aspiration et dans l'espace annulaire, ainsi que la perte de charge ont été mesurées et des correlations ont été obtenues pour ces paramètres.

On a utilisé un bilan d'énergie pour prédire les vitesses de circulation du liquide à partir des corrélations pour la rétention du gaz et pour la perte de charge. On a obtenu un accord raisonnable entre les valeurs mesurées et calculées de la vitesse de circulation.

Ancillary