SEARCH

SEARCH BY CITATION

Keywords:

  • loop reactor;
  • suspension polymerization;
  • droplet dispersing behaviour;
  • styrene polymerization

Abstract

Suspension polymerization of styrene was performed using a loop reactor. The dispersing behaviour of the droplets in the course of the reaction was observed. The mean droplet diameter was determined by the energy level at the impeller region. Moreover, the final particle size distribution and mean particle size were also determined after an elapsed time of 1-2 hrs.

An expression which correlated the final mean particle size with the operating conditions, such as the mixing conditions at the impeller region and the initial physical properties of the suspension system, was derived. The deposition of polymers on the reactor wall was found to be prevented due to the high fluid velocity.

On a réalisé la polymérisation en suspension du styrène à I'aide d'un réacteur à boucle. On a étudié la dispersion des gouttes au cours de la réaction.

Le niveau d'énergie dans la zone de I'agitateur a permis le calcul du diamètre moyen des gouttes. On a également déterminé, après un délai d'une à deux heures, la distribution finale de la taille des particules ainsi que la taille moyenne des particules.

On a calculé une expression corrélant la taille moyenne finale des particules avec les conditions opératoires, telles que les conditions de mélange dans la zone de I'agitateur et les propriétés physiques initiales des suspensions.

On a montré que la vitesse élevée du fluide permet d'éviter le dépôt de polymére sur la paroi du réacteur