Measurement of heat of mixing for ammonium chloride + ammonia system at 25 °c

Authors


Abstract

Heat of mixing for ammonium chloride in liquid ammonia at 25°C was determined in the concentration range 0-50 wt% NH4Cl. It was calculated from the differential heat of solution observed in this work and the differential heat of dilution estimated from activities of solvent. A twin isoperibol calorimeter consisting of two stainless Dewar vessels was used at a relatively high pressure (up to 1.5 MPa). The accuracy of this calorimetry was examined by measuring the heat of solution for tris-(hydroxymethyl)aminomethane(THAM) in 0.1 kmol/m3 HCl at 25°C, and satisfactory agreement within 1.1% between experimental and literature value was obtained. The reproducibility for the experiment was within 2.8%.

Abstract

On a déterminé la chaleur de mélange du chlorure d'ammonium dans de l'ammoniac liquide à 25°C pour des concentrations de NH4C1 comprises entre 0 et 50%. Cette valeur a été calculée à partir de la chaleur de solution différentielle observée dans cette étude ainsi que la chaleur de dilution différentielle estimée à partir de l'activité du solvant. On a utilisé, à une pression relativement élevée (jusqu'à 1,5 MPa), un calorimètre isopéribol jumelé composé de deux cuves Dewar en acier inoxydable. La précision du calorimètre a été vérifiée en mesurant la chaleur de solution du tris-(hydroxyméthyl)aminométhane(THAM) dans 0.1 kmol/m3 de HC1 à 25°C; on a trouvé un bon accord (variation de 1,1) entre les valeurs expérimentales et les valeurs publiées. L'erreur expérimentale est inférieure à 2,8.