An experimental study of the effect of operating conditions on the performance of a hydro-filter (marble-bed scrubber) has been conducted. The overall volumetric mass transfer coefficient, KGa, remains constant while the gas flow rate changes in the stable operating regions but increases sharply in the region above the loading point, corresponding to a sharp increase in the total pressure drop of the hydro-filter. Since the gas flow is turbulent and the liquid flow is laminar under the present experimental conditions, the value of KGa is strongly dependent on the flow conditions of the liquid and its properties, while those of the gas have less effect.

The performance of a hydro-filter as a mass transfer device is shown to be superior to other types of scrubbers although its main drawback is large pressure drop.

Nous avons mené une étude expérimentale sur l'effet des conditions opératoires sur la performance d'un hydro-filtre (épurateur à lit de billes). Le coefficient global de transfert de matière volumétrique, KGa, demeure constant lorsque le débit de gaz varie dans les régions opératoires stables mais augmente considérablement dans la région audessus du point de chargement, ce qui correspond à une forte augmentation de la perte de charge globale de l'hydro-filtre. Dans les conditions expérimentales présentes, l'écoulement gazeux est turbulent et l'éoulement liquide laminaire; la valeur de KGa dépend donc fortement des conditions découlement du liquide et de ses propriétés, tandis que l'effet de l'écoulement gazeux est moindre.

On montre que la performance d'un hydro-filtre comme dispositif de transfert de matière est supérieure è celle d'autres types d'épurateurs bien qu'il ait comme désavantage majeur une perte de charge élevée.