Cyclone collection efficiencies at very high temperatures

Authors


Abstract

Experimental results for gas-solid separations in a 102 mm diameter conventional cyclone operated with air heated to temperatures between 300 K and 2 000 K, are presented. Overall and fractional collection efficiencies were measured for alumina and silica having particle sizes of 100% less than 44 μm and mass median diameters of 5.0 and 10.0 μm respectively. Inlet velocities ranged from three to 42 m/s and inlet dust loads were between 0.3 and 235 g/m3. The dust load had a strong influence on the collection efficiency and the loading effect was stronger at high temperatures.

Abstract

On présente des résultats expérimentaux pour les séparations gaz-solides dans un cyclone conventionnel de 102 mm de diamètre fonctionnant à l'air chauffé à des températures comprises entre 300 et 2 000 K. Les efficacités de récupération fractionnelle et globale ont été mesurées pour des alumines et des silices ayant des tailles de particules à 100% inférieures à 44 μm et des diamètres moyens massiques de 5,0 et 10.0 μm, respectivement. Les vitesses d'entrée varient entre 3 et 42 m/s et les charges de poussières d'entrée entre 0,3 et 235 g/m3. La charge de poussières a une grande influence sur l'efficacité de récupération et l'effet de charge est plus grand à températures élevées.

Ancillary