Pool boiling heat transfer to saturated water and refrigerant 113

Authors


Abstract

Pool boiling heat transfer coefficients were measured for saturated water at atmospheric pressure and for saturated refrigerant Rl13 at 102 kPa and 341 kPa. The measured heat transfer coefficients were compared with values found by other researchers and with the predictions of correlations from the literature. Bubble departure diameter, bubble frequency and nucleation site density were recorded for each experiment. A pool boiling model recently developed by Blöchl and Bier is described and limitations of the model are discussed.

Abstract

Les coefficients de transfert de chaleur pour un réservoir en ébullition ont été mesurés pour l'eau saturée á la pression atmosphérique et pour le réfrigérant saturé á 102 et 341 kPa. Les coefficients de transfert de chaleur mesurés ont été comparés aux valeurs trouvés par d'autres chercheurs et aux prédictions de corrélations publiées. Le diamètre de départ des bulles, la fréquence des bulles et la densité du site de nucléation ont été enregistrés pour chaque expérience. Un modèle d'ébullition de réservoir récemment mis au point par Blöchl et Bier est décrit et les limites du modèle sont examinées.