Get access
Advertisement

Behaviour of absorption/stripping columns for the CO2-MEA system; Modelling and experiments

Authors

  • Germán P. Escobillana,

    1. Department of Chemical Engineering, Faculty of Physical and Mathematical Sciences, University of Chile, Casilla 2777, Santiago, Chile
    Search for more papers by this author
  • Jorge A. Saez,

    1. Department of Chemical Engineering, Faculty of Physical and Mathematical Sciences, University of Chile, Casilla 2777, Santiago, Chile
    Search for more papers by this author
  • José R. Pérez-Correa,

    1. Department of Chemical Engineering, Faculty of Physical and Mathematical Sciences, University of Chile, Casilla 2777, Santiago, Chile
    Search for more papers by this author
  • Heinz J. Neuburg,

    Corresponding author
    1. Department of Chemical Engineering, Faculty of Physical and Mathematical Sciences, University of Chile, Casilla 2777, Santiago, Chile
    • Department of Chemical Engineering, Faculty of Physical and Mathematical Sciences, University of Chile, Casilla 2777, Santiago, Chile
    Search for more papers by this author
  • Lester S. Kershenbaum

    1. Department of Chemical Engineering and Chemical Technology, Imperial College, London, SW7 2AZ, England
    Search for more papers by this author

Abstract

A model is presented for the steady-state simulation of a CO2 recovery pilot plant with aqueous monoethanolamine (MEA) solutions. CO2 absorption is performed in a column packed with 2.54 cm ceramic Pall rings. CO2 recovery is achieved in a 20 sieve tray steam stripping column.

The packed column absorption model was fitted to the experimental data using the specific interfacial area of the irrigated packing as an adjustable parameter. The equivalent average bubble diameter was used as the adjusting parameter in the sieve tray stripping column.

Modelling of both towers reproduces within 3% average error concentrations measured in a pilot plant. Measured temperatures were also well correlated.

Abstract

On présente un modéle de simulation à l'état permanent d'une usine pilote de récupération de CO2 avec des solutions de monoéthanolamine (MEA) aqueuses. L'absorption du CO2 est effectuée dans une colonne garnie d'anneaux de Pall en céramique de 2,54 cm. La récupération du CO2 a lieu dans une colonne de désorption à la vapeur munie de 20 plateaux perforés.

Le modèle d'absorption avec la colonne garnie a été adapté aux données expérimentales en utilisant la surface spécifique interfaciale du garnissage irrigué comme paramètre ajustable. Le diamètre moyen des bulles équivalent a été utilisé comme paramètre d'ajustement dans la colonne de désorption à plateaux perforés.

La modélisation des deux tours reproduit avec une erreur de 3% les concentrations mesurées dans l'usine pilote. Les températures mesurées ont également été corrélées.

Get access to the full text of this article

Ancillary