Prediction of axial mixing coefficients in rotating disc and asymmetric rotating disc extraction columns

Authors


Abstract

The correlation of axial mixing in the continuous and dispersed phases of rotating disc and asymmetric rotating disc columns is presented. Published experimental results on continuous-phase axial mixing for both single- and two-phase flows, obtained with tracer injection methods and by solute concentration profiles, are considered. The correlation developed is based on 1055 data points for 32 liquid systems obtained by 19 different investigators. The axial mixing in rotating disc columns is found to be up to 20% larger than in asymmetric rotating disc columns.

Data for the dispersed phase are harder to correlate than those for the continuous phase. Since the available results are often contradictory, the correlation for the dispersed-phase coefficient is thus less accurate than that for the continuousphase coefficient.

Abstract

On a établi une corrélation pour le mélange axial dans les phases dispersée et continue de colonnes à disques rotatifs ou à disques rotatifs asymétriques. On examine les résultats expérimentaux publiés sur le mélange axial de la phase continue à la fois pour des écoulements simples et des écoulements diphasiques, obtenus par des méthodes d'injection de traceur et par des profils de concentration de solutés. La corrélation établi s'appuie sur I 055 données pour 32 systèmes liquides obtenues par 19 chercheurs différents. Le mélange axial dans les colonnes à disques rotatifs s'avère 20% supérieur au mélange axial dans les colonnes à disques rotatifs asymétriques.

Les donnèes pour la phase dispersée sont plus difficiles à corréler que pour la phase continue. Les résultats disponibles étant souvent contradictoires, la corrélation pour le coefficient de la phase dispersée est moins exacte que dans le cas du coefficient de la phase continue.

Ancillary