Keywords:

  • circulating fluidized bed;
  • pressure balance;
  • L-valve;
  • riser;
  • suspension concentration

Abstract

Pressure measurements around the loop of a circulating fluidized bed with 152 mm ID riser and L-valve fecuer were analysed to determine the effect of operating parameters (superficial gas velocity in the range 2.2 - 4.0 m/s, solids circulation flux in the range 5 - 50 kg/m2 · s and solids inventory, in the range 80 - 180 kg) on the components of the pressure balance. The riser pressure drop, and hence, riser solids holdup were not affected by changes in the inventory of solids in the system, provided riser superficial gas velocity and solid circulation flux were held constant. The mean suspension concentration in the riser was found to be directly proportional to the ratio of solids flux to superficial gas velocity (G / U) in the riser.

On a analysé les mesures de pression autour de la boucle d'un lit fluidisé circulant muni d'une colonne montante de 152 mm de diamètre intérieur et d'un distributeur comportant un robinet en L afin de déterminer l'effet des paramètres opératoires (vitesse de gaz superficielle entre 2,2 et 4,0 m/s, flux de circulation des solides entre 5 et 50 kg/m2 s et bilan des solides entre 80 et 180 kg) sur les composantes du bilan de pression. La perte de charge dans la colonne montante et par voie de conséquence la rétention des solides ne sont pas modifiées par les changements survenant dans le bilan des solides dans le système, tout au moins tant que la vitesse de gaz superficielle et le flux de circulation des solides de la colonne montante demeurent constants. La concentration moyenne de suspensions dans la colonne montante s'avère directement proportionnelle au rapport entre le flux de solides et la vitesse de gaz superficielle (G / U) dans la colonne.