Abstract

The mass transfer efficiencies of dualflow trays with open hole areas of 20, 28 and 37% were experimentally investigated under total reflux conditions in a 300-mm diameter distillation column using methanol-water and methanol-isopropanol systems. The results indicate that the efficiency of a dualflow tray is a strong function of the open hole area, the vapor/liquid load, and liquid properties such as surface tension and density. A fundamental model was developed to predict tray efficiency. The prediction was found to agree with the measured data to within 15.3%.

L'efficacité du transfert de matière dans les plateaux à écoulement double avec des zones d'orifices ouvertes de 20, 28 et 37% a été étudiée expérimentalement dans des conditions de reflux totales dam une colonne de distillation de 300 mm de diamètre avec des systèmes méthanol-eau et méthanol-isopropanol. Les résultats indiquent que I'efficacité d'un plateau à écoulement double est fortement fonction de la zone d'orifice ouverte, de la charge liquide/vapeur et des propriétés du liquide telles que, la tension superficielle et la masse volumique. On a mis au point un modèle fondamental pour la prédiction de I'efficacité des plateaux. On a trouvé que cette prédiction concordait avec les données mesurées à 15,3%.