Abstract

Using the standard deviation of pressure fluctuations to find the minimum fluidization velocity, Umf, avoids the need to de-fluidize the bed so Umf, can be found for operational bubbling fluidized beds without disrupting the process provided only that the superficial velocity may be altered and that the bed remains in the bubbling fluidized state.

This investigation has concentrated on two distinct aspects of the pressure fluctuation method for Umf determination: (1) the minimum number of pressure measurements required to obtain reliable estimates of standard deviation has been identified as about 10000 and (2) pressure fluctuation measurements in the plenum below the gas distributor are suitable for Umf determination so the problems of pressure probe clogging and erosion by bed particles may be avoided.

Le fait d'utiliser l'écart-type des fluctuations de pression pour la détermination de la vitesse minimale de fluidisation, Umf, permet d'éviter de défluidiser le lit; de cette façon, la valeur de l'Umf peut ětre trouvée pour les lits fluidisés bouillonnants sans interruption du processus, à la condition cependant que la vitesse superficielle puisse ětre modifiée et que le lit reste à l'état bouillonnant.

Cette étude se concentre sur deux aspects distincts de la méthode des fluctuations de pression pour la détermination de Umf: (1) le nombre minimum des mesures de pression requis pour obtenir des estimations d'écarts-types fiables a été établi à environ 10000; (2) les mesures de fluctuation de pression dans la chambre de surpression sous le distributeur de gaz conviennent pour déterminer Umf ce qui permet d'éviter les problèmes d'encrassement et l'érosion des sondes de pression par les particles de lit.