Cold flow velocity measurements in recovery boilers: Part I: Interaction of primary and secondary air flows

Authors


Abstract

Cold air flow velocities were measured in a commercial recovery boiler during shutdown periods, using hot-wire anemometers, modified to indicate direction. Five tests were carried out using different primary and secondary air configurations. The conditions tested included arrangements recommended by others to improve gas flow uniformity, as well as unrealistic extremes to be used in the evaluation of computational fluid dynamic models. The measurements demonstrated the inherent unsteadiness of recovery boiler flows and confirmed that balanced air flows through opposed walls result in a central region of high velocity upward flow. Interlacing of the secondary air significantly reduced the peak velocity and flattened the upward velocity profile at the liquor gun level.

Abstract

On a mesuré les vitesses d'écoulement d'air froid dans une chaudière de recupération commerciale lors des périodes d'arrkt, à l'aide d'anémometres a fil chaud modifiés pour indiquer la direction. Cinq essais ont été rétalisés au moyen de différentes configurations d'air primaire et secondaire. Les conditions d'essais incluaient les dispositions recommandees dans d'autres études dans le but d'améliorer I'uniformité du débit de gaz, ainsi que des cas extrêmes non réalistes pouvant servir dans I'évaluation des modèles de simulations d'écoulement. Les mesures démontrent le caractère instationnaire des écoulements dans la chaudière de récupération et confirment que des débits d'air équilibrés a travers des parois opposees créent une région centrale d'ecoulement ascendant à haute vitesse. L'entrecroisement de l'air secondaire reduit de manière significative la vitesse pic et aplanit le profit de vitesse ascendant au niveau de l'orifice de la liqueur.

Ancillary