Pressure drops in gas—liquid flow in a 15 cm reciprocating platecolumn

Authors


Abstract

Time-averaged pressure drops have been measured in a 15 cm internal diameter reciprocating plate column, using the water/air system under conditions of cocurrent, countercurrent and single phase (water) flow. The reciprocation frequency was varied from 1 to 4 Hz, while the stroke (peak to trough amplitude) was set at 2.54 cm. Two types of perforated plate were used, having perforation diameters 14.3 and 6.35 mm.

Under single phase flow conditions, the pressure drops were in agreement with an earlier model due to Noh and Baird (1984). Under cocurrent conditions the gas flow had the effect of increasing the pressure drop, particularly at low reciprocation rates; this was interpreted in terms of enhanced circulation velocities in the liquid phase. In countercurrent flow the pressure drop was also affected by bubbles clustering at the plates.

Abstract

On a mesuré des pertes de charge moyennées dans le temps dans une colonne à plateaux réciproques de 15 cm de diamètre intérieur, au moyen d'un système air/eau dans des conditions d'écoulement monophasique (eau), à cocourant et à contrecourant. On a fait varier la fréquence de pulsation de l à 4 Hz, tandis que la course (amplitude pic-creux) a été fixée à 2,54 cm. Deux types de plateaux performés ont été utilisés, avec des diamètres de perforation de 14,3 et 6,35 mm.

Dans des conditions d'écoulement monophasique, les pertes de charge concordent avec le modèle de Noh et Baird (1984). Dans des conditions à cocourant, le débit de gaz a pour effet d'augmenter la perte de charge, particulièrement à de faibles taux de pulsation, ce que l'on a expliqué par des vitesses de circulation accrues dans la phase liquide. Dans l'écoulement à contrecourant, la perte de charge subit également l'influence de l'agglomération des bulles sur les plateaux.

Ancillary