A technique is proposed to predict the gassed power draw of mixed impeller systems as a weighted average of the gassed power draws of the individual impellers. The success of this method requires determining the gassed power draws of the individual impellers in the proper gassed environment. In the case of the upper impellers, this environment is provided by a rubber membrane sparger that distributes the gas evenly over the vessel cross section. Extensive comparisons of experimental gassed power draws of mixed impeller systems with model predictions verify the accuracy of the proposed technique.

On propose une technique afin de prédire la consommation de puissance en milieu aéré de systèmes de turbines multiples comme une moyenne pondérée de la consommation de puissance en milieu aéré des turbines individuelles. Pour réussir, cette méthode nécessite qu'on détermine les consommations de puissance en milieu aéreé des turbines individuelles dans l'environnement d'aération approprié. Dans le cas des turbines supérieures, cet environnement est fourni par un aérateur à membrane de caoutchouc qui distribue le gaz de manière égale au-dessus de la section transversale du réservoir. Des comparaisons extensives entre les consommations de puisance en milieu aéré expérimentales des systèmes de turbines multiples et des prédictions du modèle démontrent la précision de la technique proposée.