Get access
Advertisement

The onset of liquid entrainment during discharge from two branches on an inclined wall

Authors


Abstract

A theoretical investigation has been conducted for predicting the critical liquid height at the onset of liquid entrainment during dual discharge from a stratified two-phase region through branches mounted on an inclined flat wall. The centerlines of the two branches are parallel and they fall in a common vertical plane. Two models have been developed; a simplified point-sink model and a more-accurate finite-branch model. Predictions from the two models are shown to be in good agreement for the condition of high flow rates from the branches, while the finite-branch model is necessary for accurate predictions at low branch flow rates. This behaviour has been confirmed experimentally for the vertical-wall configuration.

Abstract

On a effectué une recherche théorique afin de prédire la hauteur critique du liquide au commencement de l'entraînement du liquide lors de la double décharge d'une région biphasique stratifiée dans des branches montées sur une paroi plane inclinée. Les axes des deux branches sont parallèles et tombent dans un plan vertical commun. Deux modèles ont été mis au point: un modèle de puits ponctuel simplifié et un modèle à branches finies plus précis. On montre que les prédictions des deux modèles concordent bien pour de forts débits des branches, tandis que le modèle à branches finies est nécessaire pour des prédictions précises à de faibles débits des branches. Ce comportement est confirmé expérimentalement pour la configuration à paroi verticale.

Get access to the full text of this article

Ancillary