Abstract

The steady-state method by measuring the concentration profile along the column height is an effective way, but it is a time and material consumption method for large extraction columns. In order to investigate the axial-mixing and mass transfer performances in a large pulsed-sieve-plate extraction column with the diameter of 150mm, a two-point dynamic method with mass transfer based on the diffusion model has been developed. The results proved that the two-point dynamic method has the advantages of good accuracy, simple boundary equations and flexible sampling position over the traditional single-point dynamic method. It is a reliable tool for studying the axial-mixing and the mass transfer performances.

La méthode de mesure du profil de concentration axial en régime permanent dans les grandes colonnes d'extraction est efficace mais demande du temps et des matériaux. Afin d'étudier les performances de mélange axial et de transfert de matière dans une grande colonne d'extraction pulsée à plateau perforé de diamètre de 150 mm, on a mis au point une méthode dynamique à deux points où le transfert de matière est basé sur le modèle de diffusion. Les résultats montrent que cette dernière méthode présente plusieurs avantages par rapport à la méthode dynamique à point unique classique, soient une bonne précision, des équations aux limites simples et une position d'échantillonage flexible. C'est un outil fiable pour l'étude des performances du mélange axial et du transfert de matière.