Abstract

The kinetic parameters (activation energy, pre-exponential factor and reaction order) of volatile and char of deinking sludge are determined by thermo-gravimetric analysis. From the Arrhenius plot, the activation energy and the pre-exponential factor of char are determined. The reaction order is found to be 0.7 with respect to oxygen partial pressures of 507 – 3040 Pa. The effects of riser gas velocity, solid feeding rate and annulus air on combustion efficiency have been determined in an internally circulating fluidized bed (ICFB). The combustion efficiency decreases with increasing riser gas velocity and solid feeding rate, while it increases with increasing annulus air. High combustion efficiency is obtained when the annulus air is injected.

On a déterminé par l'analyse thermo-gravimétrique les paramètres cinétiques (énergie d'activation, facteur pré-exponentiel et ordre de réaction) de produits volatils et du charbon de boues de désencrage. L'énergie d'activation et le facteur pré-exponentiel du charbon sont déterminés à partir de la courbe d'Arrhenius. On a trouvé que l'ordre de réaction était de 0,7 pour des pressions partielles d'oxygène de 507 – 3040 Pa. Les effets de la vitesse de gaz de la colonne montante, de la vitesse d'alimentation des solides et de l'air de l'espace annulaire sur l'efficacité de combustion ont été déterminés dans un lit fluidisé circulant interne (ICFB). L'efficacité de combustion diminue avec l'augmentation de la vitesse de gaz de la colonne montante et de la vitesse d'alimentation des solides, tandis qu'elle augmente avec l'augmentation de l'air de l'espace annulaire. Une efficacité de combustion élevée est obtenue lorsqu'on injecte de l'air d'espace annulaire.