SEARCH

SEARCH BY CITATION

Keywords:

  • bubble column;
  • hydrodynamic regime;
  • churn flow;
  • electrical tomography;
  • pressure fluctuations

Abstract

Knowing the hydrodynamic regime in which is working a bubble column is of great importance because the regime affects strongly the mass transfer between the phases. To this end, we examine the potentialities of an Electrical Resistance Tomography (ERT) device. We analyse cross correlation of electrode pair measurements, of neighbouring pixels and power spectra of averaged pixels within a single plane as well as cross correlations of averaged pixels between two planes, without finding a clear signature of the churn turbulent flow. Variable gas flow rate inputs are used to determine the time resolution of the ERT.

L'objet du présent travail est de déterminer dans quelle mesure la Tomographie Électrique Résistive (ERT) peut être utilisée pour détecter le régime hydrodynamique dans lequel fonctionne une colonne à bulles. La connaissance de ce régime est extrêmement importante, en raison notamment de son influence sur les valeurs des paramètres de transfert. Dans ce but, nous avons analysé les spectres de puissance de la valeur moyenne des pixels dans un plan de mesure donné, ainsi que la corrélation temporelle existant entre les mesures de différence de potentiel, entre les pixels voisins d'un plan de mesure donné et entre les valeurs moyennes des pixels appartenant à deux plans de mesure différents. Nous n'avons trouvé aucune signature claire du régime hétérogène. La résolution temporelle de l'ERT a par ailleurs été évaluée en utilisant une alimentation de gaz variable.