SEARCH

SEARCH BY CITATION

Keywords:

  • mass transfer;
  • contamination;
  • agitation;
  • combined model

Abstract

The simultaneous effect of contamination and agitation was investigated using a pilot rotating disc contactor and mass transfer in both directions with single drops in the absence of drop break-up and coalescence. It is ideally required to account for the extent of contamination in a quantitative manner and in both phases with a single parameter. In this work, a combined mass transfer model is applied and an improvement is made using an empirical coefficient and having mathematical consistency. Based on 120 experimental data series obtained for each mass transfer direction, a correlation is proposed for the coefficient of this model.

On a étudié l'effet simultané de la contamination et de l'agitation à l'aide d'un contacteur à disque rotatif pilote et du transfert de matière dans les deux directions avec des gouttes uniques en l'absence de rupture et coalescence de gouttes. Il faut idéalement prendre en compte la portée de la contamination d'une manière quantitative et dans les deux phases avec un seul paramètre. Dans ce travail, on applique un modèle de transfert de matière combiné et on apporte une amélioration en utilisant un coefficient empirique et en ayant une cohérence mathématique. D'après 120 séries de données expérimentales obtenues pour chaque direction de transfert de matière, une corrélation est proposée pour le coefficient de ce modèle.