Abstract

The working of loop seal is one of the least understood aspects of a circulating fluidized bed boiler although this component is critical to the operation of such boilers. The present work is an experimental study of the flow of solids; through the recycle chamber of a loop seal in a circulating fluidized bed (CFB). The effect of different parameters on the velocity of solid overflow through the recycle chamber is investigated. The sharp-crested weir theory of free surface water flow was used to analyze the solid flow through the loop seal. The analysis gives a good indication of the validity of the above theory for solids overflow over a weir. The results show that the solid flow rate increases with increase in bed height above the weir and the particle size had no effect on the value of the weir coefficient.

Le travail de l'obstruction en boucle est l'un des aspects les moins connus d'une chaudière à lit fluidisé circulant, bien que cette composante soit critique pour le fonctionnement de telles chaudières. On présente ici une étude expérimentale de l'écoulement des solides, dans la chambre de recirculation d'une obstruction en boucle dans un lit fluidisé circulant (CFB). On a étudié l'effet de différents paramètres sur la vitesse du trop-plein dans la chambre de recirculation. On a eu recours à la théorie de la surverse à arêtes tranchantes de l'écoulement d'eau à surface libre pour analyser l'écoulement de solides dans une obstruction en boucle. L'analyse donne une bonne indication de la validité de cette théorie pour le trop-plein de solides au-dessus d'une surverse. Les résultats montrent que le débit de solides augmente avec la hauteur de lit au-dessus de la surverse et que la taille des solides n'a pas d'effet sur la valeur du coefficient de surverse.