Abstract

Particle attrition in the rotary valve of a pneumatic conveying system was studied. The relationship between physical properties of polymer granules and attrition behaviour was compared between intact (fresh/unused) and attrited particles. It was observed that attrited particles become more breakable and have lower flowability. Experiments were conducted in a rotary valve and pneumatic conveying system separately; attrition in each case could be described by the Gwyn function. The influence of particle attrition on electrostatic characteristics was examined. Charge density of attrited particles was higher than that of intact ones, but induced current showed a reverse trend.

On a étudié l'attrition des particules dans une vanne rotative d'un convoyeur pneumatique. On a comparé pour des particules intactes (fraîches/non utilisées) et des particules usées, la relation entre les propriétés physiques de granules de polymères et le comportement d'attrition. On a constaté que les particules usées devenaient plus cassables et avaient une plus faible flottabilité. Des expériences ont été menées séparément dans une vanne rotative et un convoyeur pneumatique; dans les deux cas l'attrition pourrait être décrite par la fonction de Gwyn. L'influence de l'attrition des particules sur les caractéristiques électrostatiques a été examinée. La masse volumique de charge des particules usées est plus élevée que celles des particules intactes, mais un courant induit montre une tendance inverse.