SEARCH

SEARCH BY CITATION

Literature Cited

  • 1
    Shapiro HM. Practical Flow Cytometry, 3rd ed. New York: Wiley-Liss; 1995.
  • 2
    Janeway CA,Travers P,Hunt S,Walport M. Immunobiology: The Immune System in Health and Disease, 3rd ed. Current Biology. New York: Garland Publishing; 1997.
  • 3
    Hultin LE,Matud JL,Giorgi JV. Quantitation of CD38 activation antigen expression on CD8+ T cells in HIV-1 infection using CD4 expression on CD4+ T lymphocytes as a biological calibrator. Cytometry 1998; 33: 123132.
  • 4
    Yang OO,Ferbas JJ,Hausner MA,Hultin LE,Hultin PM,McFadden D,Sawicki M,Detels R,Majchrowicz M,Matud JL,Giorgi JV,Jamieson BD. Effects of HIV-1 infection on lymphocyte phenotypes in blood versus lymph nodes. J Acquir Immune Defic Syndr 2005; 39: 507518.
  • 5
    Crespo M,Bosch F,Villamor N,Bellosillo B,Colomer D,Rozman M,Marcé S,López-Guillermo A,Campo E,Montserrat E. Zap-70 expression as a surrogate for immunoglobulin-variable-region mutations in chronic lymphocytic leukemia. N Engl J Med 2003; 348: 17641775.
  • 6
    Chen Y,Peterson LC,Dittmann D,Evens A,Rosen S,Khoong A,Vincent Shankey T,Forman M,Gupta R,Goolsby CL. Comparative analysis of flow cytometric techniques in assessment of Zap-70 expression in relation to IgVH mutational status in chronic lymphocytic leukemia. Am J Clin Pathol 2007; 127: 182191.
  • 7
    CLSI. Fluorescence Calibration and Quantitation Measurements of Fluorescence Intensity, Approved Guideline I/LA24-A. CLSI: Pennsylvania; 2004.
  • 8
    Lambert C,Cristina I,Christian G. Enumeration of peripheral lymphocyte subsets using 6 vs. 4 color staining: A clinical evaluation of a new flowcytometer. Cytometry Part B: Clin Cytometry 2005; 70B: 2938.
  • 9
    Perfetto SP,Ambrozak D,Nguyen R,Chattopadhyay P,Roederer M. Quality assurance for polychromatic flow cytometry. Nat Protocols 2006; 1: 15221530.
  • 10
    Innovation/Stagnation: Challenge and Opportunity on the Critical Path to New Medical Products. Available at http://www.fda.gov/oc/initiatives/criticalpath/whitepaper.html.
  • 11
    Bloom ET,Epstein SL,Simek SL. Critical path workshop on the development of cellular and gene therapy products. Mol Ther 2005; 12: 58.
  • 12
    Wang L,Abbasi F,Gaigalas AK,Vogt RF,Marti GE. Comparison of fluorescein and phycoerythrin conjugates for quantifying CD20 expression on normal and leukemic B-cells. Cytometry Part B: Clin Cytometry 2006; 70B: 410415.
  • 13
    Gaigalas AK,Wang L,Schwartz A,Marti GE,Vogt RF. Quantitating fluorescence intensity from fluorophore: Assignment of MESF values. J Res Natl Inst Stand Technol 2005; 110: 101114.
  • 14
    Brejc K,Ficner R,Huber R,Steinbacher S. Isolation, crystallization, crystal structure analysis and refinement of allophycocyanin from the cyanobacterium Spirulina platensis at 2.3 Å resolution. J Mol Biol 1995; 249: 424440.
  • 15
    Liu JY,Liang T,Zhang JP,Liang DC. Crystal structure of allophycocyanin from red algae Porphyra yezoensis at 2.2 Å resolution. J Biol Chem 1999; 274: 1694516952.
  • 16
    Poncelet P,Carayon P. Cytofluorometric quantification of cell surface antigens by indirect immunofluorescence using monoclonal antibodies. J Immunol Methods 1985; 85: 6574.
  • 17
    Poncelet P,Poinas G,Corbeau P,Devaux C,Tubiana N,Muloko N,Tamalet C,Chermann JC,Kourilsky F,Sampol J. Surface CD4 density remains constant on lymphocytes of HIV-infected patients in the progression of disease. Res Immunol 1991; 142: 291298.
  • 18
    Davis KA,Abrams B,Iyer SB,Hoffman RA,Bishop JE. Determination of CD4 antigen density on cells: Role of antibody valency, avidity, clones, and conjugation. Cytometry 1998; 33: 197205.
  • 19
    Wang L,Abbasi F,Gaigalas AK,Hoffman RA,Flagler D,Marti GE. Discrepancy in measuring CD4 expression on T lymphocytes using fluorescein conjugates in comparison with unimolar CD4-phycoerythrin conjugates. Cytometry Part B: Clin Cytometry 2007; 72B: 442449.
  • 20
    Chase ES,Hoffman RA. Resolution of dimly fluorescent particles: A practical measure of fluorescence sensitivity. Cytometry 1998; 33: 267279.