SEARCH

SEARCH BY CITATION

LITERATURE CITED

  • 1
    LenkeiR, MandyF, MartiGE, VogtR, editors. Quantitative fluorescence cytometry: An emerging consensus (special issue). Cytometry 1998; 33(2).
  • 2
    Gratama JW, D'hautcourt Jean-Luc, Mandy F, Rothe G, Barnett D, Janossy G, Papa S, Schmitz G, Lenkei R. Flow cytometric quantitation of immunofluorescence intensity: Problems and perspectives. Cytometry 1998; 33: 166178.
  • 3
    Hoffman RA. Standardization and quantitation in flow cytometry. In: DarzynkiewiczD, RobinsonJP, CrissmanHA, editors. Methods in Cell Biology 63 (Cytometry), 3rd ed. San Diego, CA: Academic Press; 2000. pp 300340.
  • 4
    Schwartz A, Wang L, Early E, Gaigalas AK, Zhang Yu-Zhong, Marti GE, Vogt RF. Quantitating fluorescence intensity from fluorophore: The definition of MESF assignment. J Res Natl Inst Stand Technol 2002; 107: 8391.
  • 5
    Poncelet P, Carayon P. Cytofluorometric quantification of cell surface antigens by indirect immunofluorescence using monoclonal antibodies. J Immunol Methods 1985; 85: 6574.
  • 6
    Bikoue A, George F, Poncelet P, Mutin M, Janossy G, Sampol J. Quantitative analysis of leukocyte membrane antigen expression: Normal adult values. Cytometry 1996; 26: 137147.
  • 7
    Davis KA, Abrams B, Iyer SB, Hoffman RA, Bishop JE. Determination of CD4 antigen density on cells: Role of antibody valency, avidity, clones, and conjugation. Cytometry 1998; 33: 197205.
  • 8
    Lenkei R, Andersson B. Determination of the antibody binding capacity of lymphocyte membrane antigens by flow cytometry in 58 blood donors. J Immunol Methods 1995; 183: 267277.
  • 9
    Bikoue A, Janossy G, Barnett D. Stabilised cellular immuno-fluorescence assay: CD45 expression as a calibration standard for human leukocytes. J Immunol Methods 2002; 266: 1932.
  • 10
    Poncelet P, Poinas G, Corbeau P, Devaux C, Tubiana N, Muloko N, Tamalet C, Chermann JC, Kourilsky F, Sampol J. Surface CD4 density remains constant on lymphocytes of HIV-infected patients in the progression of disease. Res Immunol 1991; 142: 291298.
  • 11
    Hultin L, Matud JL, Giorgi JV. Quantitation of CD38 activation antigen expression on CD38+ T cells in HIV-1 infection using CD4 expression on CD4+ T lymphocytes as a biological calibrator. Cytometry 1998; 33: 123132.
  • 12
    Lenkei R, Gratama JW, Schmitz G, D'hautcourt JL, Årekrans A, Mandy F, Marti GE. Performance of calibration standards for antigen quantitation with flow cytometry. Cytometry 1998; 33: 188196.
  • 13
    Denny TN, Stein D, Mui T, Scolpino A, Holland B. Quantitative determination of surface antibody binding capacities of immune subsets present in peripheral blood of healthy adult donors. Cytometry B (Clin Cytometry) 1996; 26: 265274.
  • 14
    Serke S, van Lessen A, Huhn D. Quantative fluorescence flow cytometry: A comparison of the three techniques for direct and indirect immunofluorescence. Cytometry 1998; 33: 179187.
  • 15
    Zenger VE, Vogt RF, Mandy F, Schwartz A, Marti GE. Quantitative flow cytometry: Inter-laboratory variation. Cytometry 1998; 33: 138145.
  • 16
    Report of Investigation of RM 8640 (microspheres with immobilized fluorescein isothiocyanate) issued on February 19, 2004. The certificate includes the MESF values of the reference beads and the uncertainties of the assignments.
  • 17
    Wang L, Abbasi F, Gaigalas AK, Vogt RF, Marti GE. Comparison of fluorescein and Phycoerythrin conjugates for quantifying CD20 expression on normal and leukemic B-cells. Cytometry Part B (Clin Cytometry) 2006; 70: 410415.
  • 18
    Renzi P, Ginns LC. Analysis of T-cell subsets in normal adults-comparison of whole-blood lysis technique to Ficoll-Hypaque separation by flow-cytometry. J Immunol Methods 1987; 98: 5356.
  • 19
    Gaigalas AK, Wang L, Schwartz A, Marti GE, Vogt RF. Quantitating fluorescence intensity from fluorophore: Assignment of MESF values. J Res Natl Inst Stand Technol 2005; 110: 101114.
  • 20
    Report of Certificate of Analysis of SRM 1932 (fluorescein solution) issued on March 4, 2003. The certificate includes values of concentration, purity, and molar absorption coefficient.
  • 21
    Kim Sook-Kyung, Hancock DK, Wang L, Cole KD, Reddy PT. Methods to characterize ricin for the development of reference materials. J Res Natl Inst Stand Technol 2006; 111: 313324.
  • 22
    SjÖback R, Nygren J, Kubista M. Absorption and fluorescence properties of fluorescein. Spectrochim Acta Part A 1995; 51: L7L21.
  • 23
    Klonis N, Sawyer WH. Spectral properties of the prototropic forms of fluorescein in aqueous solution. J Fluoresc 1996; 6: 147157.
  • 24
    Whitaker JE, Haugland RP, Prendergast FG. Spectral and photophysical studies of benzo[c]xanthene dyes: Dual emission pH sensors. Anal Biochem 1991; 194: 330344.
  • 25
    Gibbon BC, Kropf DL. Cytosolic pH gradients associated with tip growth. Science 1994; 263: 14191421.
  • 26
    Buranda T, Jones GM, Nolan JP, Keij J, Lopez GP, Sklar LA. Ligand receptor dynamics at streptavidin-coated particle surfaces: A flow cytometric and spectrofluorimetric study. J Phys Chem B 1999; 103: 33993410.
  • 27
    Deka C, Lehnert BE, Lehnert NM, Jones GM, Sklar LA, Steinkamp JA. Analysis of fluorescence lifetime and quenching of FITC- conjugated antibodies on cells by phase-sensitive flow cytometry. Cytometry 1996; 25: 271279.
  • 28
    Gaigalas AK, Gallagher T, Cole KD, Singh T, Wang L. A multistate model for the fluorescence response of R-phycoerythrin. Photochem Photobiol 2006; 82: 635644.
  • 29
    CLSI. Fluorescence Calibration and Quantitation Measurements of Fluorescence Intensity; Approved Guideline I/LA24-A (ISBN 1-56238-543-7). CLSI, Pennsylvania, 2004.
  • 30
    Vogt RF, Marti GE, Schwartz A. Quantitative calibration of fluorochrome intensity for clinical and research applications of leukocyte immunophenotyping by flow cytometry. In: TyrerHW, editor. Critical Issues in Biotechnology and Bioengineering, Vol 1. New Jersey: Ablex Publishing; 1995.