Optical coherence tomography captures rapid hemodynamic responses to acute hypoxia in the cardiovascular system of early embryos

Authors


Abstract

Background: The trajectory to heart defects may start in tubular and looping heart stages when detailed analysis of form and function is difficult by currently available methods. We used a novel method, Doppler optical coherence tomography (OCT), to follow changes in cardiovascular function in quail embryos during acute hypoxic stress. Chronic fetal hypoxia is a known risk factor for congenital heart diseases (CHDs). Decreased fetal heart rates during maternal obstructive sleep apnea suggest that studying fetal heart responses under acute hypoxia is warranted. Results: We captured responses to hypoxia at the critical looping heart stages. Doppler OCT revealed detailed vitelline arterial pulsed Doppler waveforms. Embryos tolerated 1 hr of hypoxia (5%, 10%, or 15% O2), but exhibited changes including decreased systolic and increased diastolic duration in 5 min. After 5 min, slower heart rates, arrhythmic events and an increase in retrograde blood flow were observed. These changes suggested slower filling of the heart, which was confirmed by four-dimensional Doppler imaging of the heart itself. Conclusions: Doppler OCT is well suited for rapid noninvasive screening for functional changes in avian embryos under near physiological conditions. Analysis of the accessible vitelline artery sensitively reflected changes in heart function and can be used for rapid screening. Acute hypoxia caused rapid hemodynamic changes in looping hearts and may be a concern for increased CHD risk. Developmental Dynamics 241:534–544, 2012. © 2012 Wiley Periodicals, Inc.

INTRODUCTION

Congenital heart disease (CHD), the malformation of the heart during development, is one of the most common forms of birth defects (Writing Group et al.,2009). Various risk factors, both genetic and environmental, contribute to the incidence of CHDs (Marelli et al.,2007; Michael et al.,2007). Biomechanical forces exerted by the blood flow have long been hypothesized to impact cardiac development and recent studies are beginning to elucidate the role of shear stress in controlling molecular and cellular processes (reviewed in Groenendijk et al.,2007; Hierck et al.,2007). Gross alterations of hemodynamic properties at the critical looping stage have been shown to cause cardiac defects in various model systems (Hogers et al.,1997,1999; Hove et al.,2003; Reckova et al.,2003; Lucitti et al.,2006; Yashiro et al.,2007; Vermot et al.,2009), however, progress is hindered by a lack of proper imaging techniques to quantitatively identify rapid functional changes in early embryos to identify the initial responses that deflect the heart into a trajectory toward CHDs. The heart at early looping stages is relatively small in size (0.5–1 mm in length and approximately 0.3 mm in diameter), fast contracting (2–3.5 Hz for avian embryos), fragile, and undergoing rapid and three-dimensionally complex morphological changes. The heart beat is also very sensitive to environmental changes such as temperature (McQuinn et al.,2007; Vermot et al.,2009). This demands an imaging modality of high spatial resolution, fast sampling rate, easy setup, and minimal invasiveness to capture the changes of hemodynamics in the looping heart. For practical purposes, a high throughput technology, where the time for set up, image capture, and analysis is short, would also be of value for experimental studies.

While many technologies have been applied to the study of the embryonic heart (reviewed in Nieman and Turnbull,2010; Tobita et al.,2010; Berrios-Otero et al.,2012), previous acute functional assays on fetal hemodynamics were mostly performed using ultrasound pulsed-Doppler (Phoon,2006; Spurney et al.,2006; McQuinn et al.,2007) with a typical axial resolution of 30 microns and a much more limited lateral resolution. While this is sufficient for interrogating hearts at later stages, the lack of spatial resolution and the requirement of direct acoustic contact with the sample make it less ideal for looping stage hearts. Optical coherence tomography (OCT) is a relatively new imaging technique (Huang et al.,1991; Gu et al.,2010; Walther et al.,2011), that is well suited to study hemodynamics in early embryos because of the high resolution that it can achieve (typically 10 microns) and its penetration depth (1–2 mm) is well suited for the study of tiny embryos (Jenkins et al.,2011). The OCT penetration is much deeper than can be achieved using microscopy techniques and allows imaging of the entire heart in vivo during early cardiogenesis (reviewed in Gu et al.,2010). Furthermore, this method requires no contact and is nondestructive, enabling observations of fragile avian embryos in vivo and under physiological conditions (Jenkins et al.,2010,2011). Recent development in frequency-domain OCT and image-based retrospective gating (Gargesha et al.,2009) shed new light on the contraction dynamics of the early tubular heart (Jenkins et al.,2007), and also enabled rapidly collection of four-dimensional (4D) images of the beating heart to make direct hemodynamic measurements (shear stress, cardiac output, and stroke volume; Jenkins et al.,2010).

Here, we show that when operating in the M-mode (similar to Doppler ultrasound imaging), Doppler OCT can generate pulsed Doppler waveforms at high temporal and spatial resolutions at the vitelline vessels, enabling rapid phenotypic screening of hemodynamic changes under various perturbation conditions. Because the vitelline vessel flow dynamics reflect the cardiac dynamics, this method of analyzing the morphologically simpler vitelline vessel can be used in screening for alterations of cardiac function to identify embryos that can then be subjected to the more time-consuming analysis of the beating heart itself.

To demonstrate the utility of this imaging technology, we choose hypoxia, a well-documented perturbation, for our current study. Under certain conditions, an insufficient oxygen supply (hypoxia) can occur in utero, which could lead to cardiac malformation (Webster and Abela,2007; Patterson and Zhang,2010). Conditions leading to hypoxia-related CHDs in humans include placental insufficiency (Thornburg et al.,2010), smoking (Hafström et al.,2005; Feng et al.,2010), chemical exposure (Steeg and Woolf,1979; Arbeille et al.,1997), and extreme high altitude (Chen et al.,2009). Recent studies indicate that altered hemodynamics can also lead to CHDs (Rychter and Rychterova,1981; Hogers et al.,1997; Forouhar et al.,2006; Culver and Dickinson,2010), suggesting that hypoxia can exert its effects on heart development through altered hemodynamics and potentially mechanotransduction pathways. Long-term exposure of avian embryos to severe hypoxia can decrease heart rates (Mortola et al.,2010), although a decrease to 15% oxygen did not significantly alter the embryonic heart rate (Sharma et al.,2006; Mortola et al.,2010). A similar decrease of fetal heart rate was also observed in a murine model (Furukawa et al.,2007). CHDs have been reported after prolonged hypoxic exposure (Ghatpande et al.,2008; Tintu et al.,2009; Wikenheiser et al.,2009). However, most of these experiments expose chick embryos to prolonged periods of hypoxia, and hemodynamic responses within the first hour are generally not measured. On the other hand, acute hypoxia in human pregnancy can arise with conditions such as obstructive sleep apnea (OSA) of the mother, during which slower fetal heart rates were reported (Roush and Bell,2004; Domingo et al.,2006). Whether these acute events increase the risk for CHDs is still open for debate (Sahin et al.,2008; Ayrım et al.,2011). We decided to measure acute hemodynamic responses to various degrees of hypoxia using the avian embryo as our model system to validate our OCT imaging protocols for rapid screening of phenotypes. In the process we hoped to increase our understanding of how embryos respond to acute hypoxia with the enhanced spatial and temporal resolutions associated with OCT technology.

RESULTS

Acute Hypoxic Exposure Does Not Reduce Embryo Survivability

Stage 17 (Hamburger and Hamilton,1992) quail embryos in shell-less culture were exposed to hypoxia for 1 hr, and then switched to ambient air (21% oxygen) for an additional 48 hr. The number of surviving embryos was recorded for the next 48 hr and analyzed with the Kaplan-Meier model (Kaplan and Meier,1958; Fig. 1). Under all three hypoxic conditions, more than 80–90% of the embryos survived to the end of the 48-hr observation period and no statistically significant changes in mortality were detected. However, for the first 24-hr postexposure, there was a significant increase of mortality for embryos exposed to 5% oxygen (from 0% to 20%). This increase of mortality was limited only to the first 24 hr, and there was no additional risk for the next 24-hr period. Our explanation is that some embryos (approximately 15%) might be weaker and 5% oxygen merely accelerates the process of their dying; and for those embryos that were otherwise healthy, there was no additional risk associated with acute 1-hr hypoxia. Our result indicated that quail embryos in shell-less culture tolerated acute hypoxia very well without a significant increase in mortality, and the hemodynamic measurements obtained within 1 hr could still be considered to be under physiological conditions. We also performed experiments in which embryos were exposed to hypoxic conditions for longer times. Embryos exposed to 5% oxygen for longer than 1 hr exhibited a much stronger adverse effect with none of the embryos surviving for more than 24 hr of hypoxia exposure. On the other hand, embryos exposed to 10% or 15% oxygen survive normally under prolonged exposure up to 48 hr (data not shown).

Figure 1.

Survival of quail embryos post hypoxic exposure. The quail embryos (stage 17) were exposed to different degrees of hypoxia for 1 hr. Normal oxygen (21%) was restored at the end of the hypoxic exposure period, represented in the figure as 0 hr. Embryos were cultured for another 48-hr period, and the numbers of surviving embryos were plotted as a percentage at different time points.

Hemodynamics Are Significantly Altered During the 1-Hour Hypoxic Exposure

At stage 17 of development, quail embryos were prepared in shell-less culture and the left vitelline vessels (left omphalomesenteric artery or LOMA, shown in Fig. 2A) of the developing quail embryos was located under the real-time OCT display. Operating in B-scan mode (2D scanning mode), both the artery and vein were readily identified by OCT with the artery commonly lying deeper (Fig. 2B). After switching to the M-mode (1D data acquisition over time), images were collected at the midline of the artery (dotted line in Fig. 2B), and the Doppler shift was calculated and displayed (Fig. 2C). This M-mode colored Doppler display showed pulsatile blood flow patterns typical for arteries, with the red color indicating forward blood flow and the blue color indicating retrograde blood flow (Fig. 2C). A seven-pixel segment was chosen at the center of the colored Doppler signal (dotted line in Fig. 2C), and the pulsed Doppler waveform was computed and displayed (Fig. 2D).

Figure 2.

Doppler OCT can provide high resolution pulsed Doppler waveforms at the position of the vitelline artery for hemodynamic measurements. A: Microscopic view of a stage 17 quail embryo connected to the extraembryonic vasculature spreading over the yolk in an ex ovo shell-less culture. The black bar indicates the location of the vitelline vessels that was scanned for OCT imaging. B: B-scan OCT image of the vitelline vessel. LOMA, left omphalomesenteric artery; LOMV, left omphalomesenteric vein. C: Colored Doppler image at the midline of LOMA (dashed line in Fig. 1B). The red color indicates forward blood flow, and the blue color indicates retrograde blood flow. D: Pulsed Doppler images at the center of LOMA (blue dashed line in Fig. 1C). The magnitude of the signal indicates relative flow velocity with positive values representing forward blood flows. Max, maximal flow; Min, minimal flow (or maximal retrograde flow); and Avg, timed-average flow.

The same measurements were also made when the same embryos were exposed to air with reduced oxygen. When compared with the waveforms before the exposure, significant changes of the shape of the waveforms were detected as early as 5 min after the start of hypoxic exposure (Fig. 3A,B).

Figure 3.

Changes in hemodynamic parameters, bradycardia, and missing contractions were observed under hypoxic exposure. A,B: Pulsed Doppler images of a stage 17 quail embryo before and after exposure to 10% oxygen for 5 minutes. Arrow in (B) indicates increased retrograde blood flow. C: Embryo heart rate under different degrees of hypoxia for one hour. Numbers were averaged from 6 individual embryos in each group, and plotted as averages and standard errors (indicated by the error bars). D: Pulsed Doppler image from a stage 17 quail embryo exposed to 10% oxygen for 1 hr. Arrow indicates a missing contraction with increased retrograde blood flow during the missing beat. Dotted lines indicate time intervals between consecutive heart beats.

We first measured well-established indices such as the pulsatility index (PI) and the resistance index (RI). These indices developed in the 1970s are widely used in Doppler ultrasound (Gosling et al.,1971; Planiol et al.,1974). They offer an overall measure of the blood flow characteristics in the arteries or heart using a single value which is not sensitive to the absolute blood flow velocity and can be easily obtained (Thompson et al.,1988). From the pulsed Doppler waveform, both indices can be easily calculated with high reproducibility from one heart beat cycle to another. Our results showed that while RI showed no significant differences, the PI of embryos exposed to either 10% or 5% oxygen is significantly increased as early as 5 min from the start of the exposure to hypoxic conditions (Fig. 3A,B). In addition, some other changes were also detected. The heart rate of the embryos gradually decreased during the 1-hr exposure (Fig. 3C), and in certain cases when the embryos were exposed to 5% or 10% oxygen, we also observed missing beats in a subset of the embryos (Fig. 3D). Although a small number of embryos exposed to 10% oxygen were occasionally arrhythmic, prolonged arrhythmias were only observed under the most severe hypoxic condition (5% oxygen) and the embryos would likely perish shortly after persistent arrhythmia, which might explain the increase of embryo mortality during the first 24-hr period postexposure. In addition, we also observed a slight increase in retrograde blood flow in approximately 50% of the embryos exposed to 10% or 5% oxygen (Fig. 3B), but this increase was not consistently observed under 15% oxygen.

Hypoxia Slows the Fetal Heart Rate

We performed quantitative analysis on the pulsed Doppler waveforms obtained from embryos exposed to either 15%, 10%, or 5% oxygen (n = 6 for each group). We excluded embryos that exhibited arrhythmia during the imaging session. The first parameter measured was the heart rate (Fig. 3C). By stage 17, quail embryos have a stable heart rate at approximately 200–220 beats per min with no significant increase with developmental stages until stage 24 (Pearson et al.,1998). This enabled us to directly compare the heart rate before and after the hypoxic exposure even as the embryo continued to develop during the course of the experiment. Our result confirmed that stage 17 quail embryos had an average heart rate of 210 beats per min (Fig. 3C, 0 min time point). Although a mild hypoxic exposure (15% oxygen) had no significant influence on the heart rate, both 10% and 5% oxygen exposure significantly lowered the heart rate. The changes were correlated with the length and severity of the hypoxic exposure. That is, the longer the exposure, the slower the heart rate; the more severe the hypoxia, the slower the heart rate. For example, at 5% oxygen the heart rate dropped from 210 beats per min to approximately 150 beats per min after only 25 min of exposure. However, these changes were mostly temporary. After the 1-hr hypoxic exposure, once the air was replaced with an ambient oxygen concentration of 21%, the heart rate gradually rose to normal levels (data not shown). The decrease of heart rate under hypoxia is consistent with previous findings under slightly different exposure protocols (Sharma et al.,2006; Mortola et al.,2010).

Because a slower heart rate indicates changes in the duration of different phases of the cardiac cycle, we measured the average systolic and diastolic time (shown in Fig. 3A,B). As expected, the mild 15% oxygen exposure caused no changes in either phase (Fig. 4A,B). The more severe hypoxic exposures, on the other hand, affected the phases in a complicated manner. The systolic time showed an initial decrease from 100 msec to 90 msec; it recovered to the normal levels with 10% oxygen exposure, but continued to increase to 130 msec with 5% oxygen exposure (Fig. 4A). The diastolic time showed a rapid increase at 5% and 10% oxygen (after only 5 min), with a much more dramatic increase under 5% oxygen exposure (from 200 msec to 300 msec, Fig. 4B). Statistically, there was no further increase with longer exposure (Fig. 4B). The increased duration of systole and diastole can explain the decreased heart rate. The diastolic phase was the more dominant factor because its increase was much more dramatic. This suggested that the heart spends a longer time filling, but once it is fully filled it has no major difficulties and, therefore, takes no extra time to pump the blood out to the arteries.

Figure 4.

A,B: Hypoxic exposure alters the systolic time, the diastolic time, and the relative shoulder height. Quail embryos were exposed to various degrees of hypoxia for 1 hour, and systolic and diastolic time was measured based on the pulsed Doppler images taken from the left omphalomesenteric artery (LOMA). Relative shoulder height is defined as the ratio of the secondary peak velocity to the primary peak velocity. All numbers are averaged from 6 independent observations, and plotted as averages and standard errors. Asterisks indicate that values were statistically different from controls (prior to the hypoxic exposure) with a P value less than 0.05.

Doppler Waveforms Reveal Other Hemodynamic Changes Under Hypoxia

During the analysis, we also consistently observed the small “shoulder” on the right side of the main forward flow peak. This shoulder has been observed in some occasions with Doppler ultrasound (Spyridopoulos et al.,2010) but has not been studied extensively due to the poor temporal resolution and noisy nature of Doppler ultrasound signals. In addition, the regions selected for analysis in M-mode Doppler ultrasound is generally large, and the heterogeneity of the velocity profile within the selected region often obscures this very subtle transition. In general, users of Doppler ultrasound used another index, A/B ratio, which can be obtained more consistently regardless of data quality (Stuart et al.,1980; Thompson et al.,1988). A/B ratio is the ratio of peak systolic flow and end-diastolic flow, which is a measurement of systolic/diastolic ratio (also referred to as S/D ratio). However, in our case, A/B ratio is technically meaningless due to the persistent retrograde flow at the end of diastole, rendering this ratio negative and unable to reflect the ratio of systolic/diastolic. However, we reliably observed the small secondary flow peak with distinct boundaries (Figs. 2D, 3A,B) because the Doppler M-mode measurement comes from a much more precise location and the velocity profile within is more uniform. Accurate measurements could, therefore, be made of its maximal flow. As a result, we could calculate the ratio of the secondary peak over the primary peak and obtain a systolic/diastolic ratio that is a more direct measure than the conventional A/B ratio. When we measured the relative height of this “shoulder” against the maximal forward flow, there was a significant decrease after 25 min of exposure under the more severe 10% and 5% oxygen concentration. The mild hypoxia (15% oxygen) showed no statistically significant changes. Because the systolic time is not significantly affected by hypoxic exposures, the observed decrease of this ratio suggests a less vigorous blood filling of the heart during diastole. This is consistent with our earlier observation of increased diastolic time, because it takes longer to fully fill the heart chamber before the next contraction can start.

4D Doppler Profiles in the Beating Heart Under Hypoxic Conditions

From the pulsed Doppler waveforms obtained from the vitelline arteries, we deduced what might be happening inside of the heart. Based on our analyses, we hypothesized that the heart must have a prolonged phase during blood filling. To directly test this hypothesis, we performed 4D OCT imaging on a stage 14 quail heart before and after 1-hr of 5% oxygen exposure (see Supp. Movie S1, which is available online).

To perform the experiment, we took an approach that is described in more detail in our earlier publications (Jenkins et al.,2010). As it currently takes a much longer time to collect and process the whole 4D dataset from the three-dimensionally complex looped heart than from the tubular vitelline artery, we limited our analysis to only one experimental condition (stage 14 embryo, 5% oxygen, 1-hr exposure time). We could, however, use the same 4D dataset to make more advanced measurements (e.g., shear stress, or contractile wave propagation velocity) in the future. We chose not to image stage 17 quail embryos for practical reasons. The OCT imaging system has limited penetration depth and allowed a much better view at stage 14 than at stage 17. Furthermore, the response to hypoxia of the stage 14 embryo proved to be similar to the stage 17 embryo. The blood flow at both the inflow and outflow portion of the heart is easily detected by Doppler OCT, as shown in the movie, whereas the top of the heart tube shows little Doppler signal due to the incident angle of the light being nearly perpendicular to the flow direction. When the Doppler profile under hypoxia was compared with the normoxic control, the blood flow velocity at the inflow side appeared to be significantly lower. In addition, the heart appeared to “pause” at the end of the filling stage before the forward contraction began, which was predicted from our waveform analysis of a prolonged diastolic phase measured at the vitelline artery. The blood flow patterns obtained directly from the beating heart confirmed what we deduced from the observations made in the vitelline arteries with M-mode pulsed Doppler waveform analyses.

DISCUSSION

Doppler OCT Provides High Resolution Pulsed Doppler Waveforms That Can Be Used to Measure Hemodynamic Parameters

During fetal cardiovascular system development, shear stress induced by blood flow has been demonstrated to play important roles (Culver and Dickinson,2010). The traditional approach to obtain such information is to use M-mode Doppler ultrasound (Clark et al.,1986; Hu and Clark,1989; McQuinn et al.,2007; Oosterbaan et al.,2009). However, ultrasound has limited spatial resolution which limits its usefulness during early embryonic development where the size of the heart tube or vessels of interest are less than 250 μm in diameter. Compared with Doppler ultrasound, Doppler OCT may have significant advantages when imaging early embryos because of its high spatial and temporal resolution. The typical waveform obtained with OCT clearly displays features that are difficult to detect in ultrasound waveforms. For example, we reliably demonstrated the small retrograde flow leading to the upstroke of each heart beat (Fig. 2D), which is harder to identify with ultrasound. We also demonstrated a clear “shoulder” wave following the systolic contraction (Fig. 2D), which is also harder to define with ultrasound. With pulsed ultrasound, the signal is derived from a much larger region of interest (ROI) compared with Doppler OCT. When a larger region is selected, the region often encompasses extraneous tissues (e.g., vessel wall) that can increase the noise. The blood flow inside a blood vessel can be viewed as having a parabolic profile with the velocity at the center being highest, and that near the vessel wall being the lowest. A larger ROI leads to a wide distribution in velocities, and the result is a wide distribution on the pulsed Doppler waveforms. Also, our 4D movie demonstrates that the pulsed waveforms vary greatly over a small region (inflow vs. outflow) which means that the larger ROI in pulsed Doppler ultrasound may lead to the combination of several unique waveforms into one composite trace. A smaller region of interest can be selected for Doppler OCT, thereby minimizing noise in the signal from the overlapping signals and extraneous tissue. Also, Doppler OCT and ultrasound signals are generally noisy and require averaging to produce reliable signals. The increased spatial and temporal (8 μsec/A-scan) resolution of OCT can be used for signal averaging to increase the signal to noise ratio. In general, we have seen a much more clearly defined trace in the waveforms than can be obtained with ultrasound (Fig. 2D), which enabled us to detect more subtle features such as the “shoulder” and the retrograde blood flows. However, OCT has less penetration depth than ultrasound, usually approximately 1–2 mm. This might limit its use when studying late-stage embryos or adult animals. Ideally, OCT would be used for early-stage observations and ultrasound for late-stage observations.

Here, we demonstrated that by using Doppler OCT, we can generate pulsed Doppler waveforms from locations such as the vitelline arteries in an early avian embryo. These waveforms can be analyzed to offer informative details about the functions of the heart. This approach has several advantages, including an easy setup, high spatial and temporal resolutions, and rapid analysis of data. Combined with a culture chamber to closely control environmental conditions, this method offers a noninvasive means to perform longitudinal studies. This is particularly important for developmental biology studies, due to high variances in stage within incubation days and within a stage among individual embryos especially at early stages. A longitudinal study offers internal controls before and after any interventions or treatments, thus reducing the numbers of specimens needed to perform experiments. Using M-mode Doppler OCT, an observation can be made in only a few minutes, which is also essential for short-term experiments such as in the study of acute responses to hypoxic exposure. For example, after 5 min of exposure to hypoxia, embryos initially responded by transiently shortening systolic time. This could help to explain the initial increase of the heart rate observed by Sedmera et al. in their explanted heart model (Sedmera et al.,2002). This illustrates that the looping heart responds to stimuli very quickly, therefore, it is important to have an easy setup and ability to record data quickly. In the future, we plan to modify our imaging protocol to allow continuous data recording. This will also allow studies related to intermittent arrhythmias. Our current imaging protocol can only capture arrhythmia events if they happen to fall inside our short recording time windows.

Pulsed Doppler Waveform Analysis Is Suitable for Initial Screens

A Doppler signal is only sensitive in the direction of the incident beam, and the flow information perpendicular to the beam direction is lost during the measurement. To obtain the actual flow velocity, the angle between the beam and the flow direction has to be measured (Wang et al.,2007; Jenkins et al.,2010). On the other hand, the pulsed Doppler waveform ignores such corrections and displays its result as a normalized flow pattern vs. time. There are several advantages; (1) the shape of the waveform is not affected by the angle between the beam and the flow, and (2) the region of interest does not have to be in the center of the vessel. As a result, we can operate in M-mode with a single line-scan passing through the artery. Therefore, as an initial screen, pulsed Doppler OCT in M-mode is much simpler to set up and the benefit in temporal resolution outweighs the loss (cannot obtain absolute velocity information).

After analyzing the pulsed Doppler waveforms obtained from the vitelline vessels, we inferred that the embryonic heart had a prolonged filling stage under hypoxia. This was confirmed by 4D Doppler imaging performed directly on the embryonic heart that showed weaker filling and a pause at the end of diastole. Therefore, we conclude that pulsed Doppler waveform analyses performed at the vitelline vessels can offer a quick and easy preview of what might be happening in the heart. It is well suited as a tool for initial screening for functional changes before more elaborate techniques are used to undertake the more complex and time-consuming cardiac function analyses in the heart. In this study, we used 4D Doppler imaging only to visually verify the change of cardiac function; however, precise measurements (e.g., wall shear stress, myocardial strain, and stretch) can be obtained based on the same dataset in the future, and these more advanced measurements can greatly contribute to our understanding of biomechanical forces within the heart and their roles to cardiac development.

Acute Hypoxia Can Rapidly Change Hemodynamics of the Embryo

Previous studies on hypoxia were mostly focused on long-term exposures (Arbeille et al.,1997; Hafström et al.,2005; Naňka et al.,2006; Sharma et al.,2006; Webster and Abela,2007; Ghatpande et al.,2008; Nanka et al.,2008; Tintu et al.,2009; Wikenheiser et al.,2009; Patterson and Zhang,2010), where the transcriptional activity of HIF-1 and HIF-2 are likely to play a role in the outcome (Compernolle et al.,2003; Webster and Abela,2007; Xu et al.,2007; Wikenheiser et al.,2009; Patterson and Zhang,2010). Although there were reports of decreased heart rate, it was not possible to determine whether this was due to the roles of HIF or other factors because of the length of hypoxia exposure and the time when the function was assessed (Mortola et al.,2010). We have presented compelling evidence that some aspects of hemodynamics can be altered by hypoxia as early as 5 min, which is too rapid to be accounted for by HIF-mediated transcriptional regulation. We do not yet know the mechanisms of such alterations; although it seems reasonable to hypothesize that hypoxia may change the energy balance of the cell (Budinger et al.,1996) and cause changes in cardiac contraction or conduction. Hemodynamic changes have been proposed as a mechanism for CHDs (Culver and Dickinson,2010), however, we do not yet know if the changes associated with acute hypoxia can produce developmental defects. Our survival analyses indicated no significant increase in mortality with the exception of exposure to 5% oxygen concentration. Even under the most severe condition, hypoxia appears to only shift the time of death for the weakest embryos, as 15–20% of them died during the first 24 hr instead of the second 24-hr period. Temporary hypoxia in humans can result from conditions such as obstructive sleep apnea where fetal heart rate deceleration has been reported in such cases (Roush and Bell,2004; Sahin et al.,2008). It is important to understand the link between hypoxia, hemodynamics, and CHDs, to properly access the risks to the fetus in these situations. Our results suggested that such intermittent hemodynamic changes may not result in cardiac defects in healthy individuals; however, if combined with other risk factor for CHDs, they may still have significant impact on fetal outcome. Further experiments are clearly warranted to fully elucidate those connections.

Even in prolonged hypoxic exposure, we can conclude that HIF-mediated transcriptional events are not the only pathways involved. Hypoxia itself can alter the blood flow pattern before HIF-1 or HIF-2 can perform their gene regulatory functions. Although HIF activation may still contribute to the process, including a potential adaptive response to hypoxia, non-HIF related targets might need to be considered for therapy and prevention. It is known that shear forces or cyclic strains can also alter gene expression (Awolesi et al.,1994; Pearce et al.,1996; Azuma et al.,2000; Dekker et al.,2002), some of which are shown to be important in cardiovascular development, such as in the activation and up-regulation of eNOS (Kumar et al.,2008), klf2 (Lee et al.,2006), and p-ERK (Liberatore and Yutzey,2004; Krenz et al.,2005). ERK phosphorylation happens within 5 min of altered shear stress (Pearce et al.,1996; Azuma et al.,2000), and, therefore, might mediate effects seen in acute hypoxia. Thus the regulatory mechanisms that drive the responses of the cell or tissue to adapt to hypoxia likely include both HIF-dependent and HIF-independent mechanisms. The HIF-independent mechanisms could include rapid responses of the heart that alter function that in turn can alter gene expression through mechanotransduction pathways.

In conclusion, Doppler OCT of the accessible vitelline artery sensitively reflected subtle changes in function of the looping avian heart. This method could be useful as a rapid screen to identify embryos with functional changes in cardiac function. Using this method, we found that acute hypoxia caused rapid hemodynamic changes including an increase in retrograde flow in looping hearts that may be a concern for increased CHD risk.

EXPERIMENTAL PROCEDURES

Quail Egg Incubation and Shell-less Culture

Fertilized quail eggs (Cortunix contunix communis; Boyd's Bird Company, Inc., Pullman, WA) were incubated in a humidified, forced draft incubator (G.Q.F. Manufacturing Co., Savannah, GA) at 38°C for 48 hr. Each egg was removed from the incubator, the shell removed and the content of the egg was placed in a sterilized 35-mm Petri dish (Dunn,1974). This shell-less culture was placed in a humidified tissue culture incubator (New Brunswick Scientific, Edison, NJ) at 38°C until imaging.

OCT Imaging Setup and Imaging Protocol

The OCT imaging system used in this study was a custom-built swept source OCT system, using a buffered Fourier Domain Mode Locked (FDML) laser (Huber et al.,2006a,b), which operates at a 117 kHz line rate. The axial resolution of the system was 8 μm in tissue and the lateral resolution was ∼10 μm (Jenkins et al.,2011) At stage 17 of development, quail embryos were prepared in a shell-less culture and the left side of the vitelline vessels was imaged with the OCT system as described in the Results section (Fig. 2). The real-time B-scan was scanned at 500 lines per image (Fig. 2B). For the Doppler measurements, the OCT system was operated at slower line rate (29 kHz) to improve sensitivity to Doppler shift caused by blood flow (Fig. 2C).

Pulsed Doppler Waveform Analysis

Pulsed Doppler waveforms are generated using Matlab (MathWorks, Massachusetts), and both heart rate and common indices such as pulsatility index (PI; Gosling et al.,1971) and resistance index (RI; Planiol et al.,1974) were calculated with Matlab. PI and RI are defined by:

equation image

where Max is the maximal Doppler shift, Min is the minimal Doppler shift, and Avg is the time-averaged Doppler shift.

We also measured other parameters that are defined as following. Relative “shoulder” height is defined as the ratio of secondary peak height (h2) to the main peak height (h1 or Max; Fig. 2D). We next define time point t2 as the start time of the secondary peak; t1 is the corresponding time point during the upstroke with the same Doppler shift as t2. The time span from t1 to t2 is defined as systolic time, and the rest of the heart cycle is defined as diastolic time (Fig. 2D).

4D Doppler OCT of the Embryonic Heart

Each embryo in shell-less culture was placed under the OCT system at approximately 50–53 hr of development. The developing heart imaged at 70 parallel slices, which were parallel to the body axis and spaced every 20 μm. At each slice position, 70 B-scan images (1,000 lines per image, 1.5 μm between each line) were taken before the scanner moved to the next slice position. After all the data were collected, an image-based retrospective gating algorithm (Gargesha et al.,2009) was used to reconstruct the beating heart in three dimensions. The Doppler shift was calculated and the phase was unwrapped (Goldstein et al.,1988) and displayed as an overlay to the structure image using Matlab (Jenkins et al.,2010).

Imaging Chamber Setup and Hypoxic Exposure Protocol

Quail embryo cultures were placed in a hypoxia chamber with a transparent lid. The oxygen concentration in the chamber was monitored by a gas oxygen controller (ProOx360, BioSpherix, Lacona, NY). The hypoxia chamber was housed in a humidified culture incubator, where the temperature and humidity were controlled to maintain the developing embryo under physiological conditions (Jenkins et al.,2011). During hypoxic exposure, the gas oxygen controller controlled the slow release of nitrogen gas into the hypoxia chamber until the desired oxygen concentration was reached. For the acute hypoxic exposure, the embryos were exposed to decreasing oxygen concentration at 15%, 10%, or 5% (regular ambient air contains 21% oxygen) for 1 hr then returned to normoxia. During the 1-hr exposure, pulsed Doppler waveforms were recorded in the vitelline artery at 5, 15, 25, 35, 45, and 60-min time points, and compared with those measured before the hypoxic exposure (0 min, and 21% oxygen concentration).

Survival Analysis After Short-Term Hypoxic Exposure

After incubation for 48 hr, shell-less cultures were made as described earlier and placed in the humidified culture incubator and cultured for another 24 hr at 38°C. Afterward, the surviving embryos (usually >90% survival rate) were exposed to either hypoxic conditions (15%, 10%, or 5% oxygen) for 1 hr, or control conditions (no change in oxygen concentration). After 1 hr of hypoxic exposure, the embryo's environment was changed back to a normal oxygen concentration. During the next 48 hr, the survival of the cultures was recorded at 6-hr intervals. A statistical analysis was performed to identify any potential increase in mortality after 1 hr of acute hypoxic exposure.

Statistical Analysis

All statistical analyses were performed with the software package SPSS (IBM Corporation, Somers, NY), and a P value of 0.05 is used to establish statistical significance. The Kaplan-Meier survival analyses (Kaplan and Meier,1958) were performed for both the short-term survival (24-hr postexposure) and long-term survival (48-hr postexposure). For the pulsed Doppler waveform analyses, one-way ANOVA was performed to identify potential significant differences, and the Tukey's post hoc comparisons were performed only when significant differences existed.