Potentiostatic Electrochemical Preparation of Bismuth Nanoribbons and its Application in Biologically Poisoning Lead and Cadmium Heavy Metal Ions Detection

Authors

  • Rajkumar Devasenathipathy,

    1. National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan fax: +886 2270 25238; tel: +886 2270 17147
    Search for more papers by this author
  • Raj Karthik,

    1. National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan fax: +886 2270 25238; tel: +886 2270 17147
    Search for more papers by this author
  • Shen-Ming Chen,

    Corresponding author
    1. National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan fax: +886 2270 25238; tel: +886 2270 17147
    • Shen-Ming Chen, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan fax: +886 2270 25238; tel: +886 2270 17147

      V. S. Vasantha, Post Graduate and Research Department of Chemistry, Thiagarajar College, Madurai-625009, Tamil Nadu, India

      Bih-Show Lou, Chemistry Division, Center for General Education, Chang Gung University, Wen-Hwa 1st Road, Kwei-Shan, Tao-Yuan 333, Taiwan

    Search for more papers by this author
  • Veerappan Mani,

    1. National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan fax: +886 2270 25238; tel: +886 2270 17147
    Search for more papers by this author
  • V. S. Vasantha,

    Corresponding author
    1. Post Graduate and Research Department of Chemistry, Thiagarajar College, Madurai-625009, Tamil Nadu, India
    • Shen-Ming Chen, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan fax: +886 2270 25238; tel: +886 2270 17147

      V. S. Vasantha, Post Graduate and Research Department of Chemistry, Thiagarajar College, Madurai-625009, Tamil Nadu, India

      Bih-Show Lou, Chemistry Division, Center for General Education, Chang Gung University, Wen-Hwa 1st Road, Kwei-Shan, Tao-Yuan 333, Taiwan

    Search for more papers by this author
  • M. Ajmal Ali,

    1. Department of Botany and Microbiology, College of Science, King Saud University, Riyadh 11451, Saudi Arabia
    Search for more papers by this author
  • Mohamed S. Elshikh,

    1. Department of Botany and Microbiology, College of Science, King Saud University, Riyadh 11451, Saudi Arabia
    Search for more papers by this author
  • Bih-Show Lou,

    Corresponding author
    1. Chemistry Division, Center for General Education, Chang Gung University, Wen-Hwa 1st Road, Kwei-Shan, Tao-Yuan 333, Taiwan
    • Shen-Ming Chen, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei 106, Taiwan fax: +886 2270 25238; tel: +886 2270 17147

      V. S. Vasantha, Post Graduate and Research Department of Chemistry, Thiagarajar College, Madurai-625009, Tamil Nadu, India

      Bih-Show Lou, Chemistry Division, Center for General Education, Chang Gung University, Wen-Hwa 1st Road, Kwei-Shan, Tao-Yuan 333, Taiwan

    Search for more papers by this author
  • Fahad M. A. Al-Hemaid

    1. Department of Botany and Microbiology, College of Science, King Saud University, Riyadh 11451, Saudi Arabia
    Search for more papers by this author

Abstract

A simple and elegant electrochemical potentiostatic method has been described for the preparation of highly stable and electrocatalytically active bismuth nanoribbons (BiNRs). The average length and width of the BiNRs were of 100±50 nm and 10±5 µm, respectively. Here, disodium ethylene diamine tetraacetate was employed as a scaffold for the growth of BiNRs. The formation of BiNRs was confirmed by surface morphological, elemental and cyclic voltammetric analyses. The BiNRs exhibited excellent electrocatalytic ability in detecting biologically poisoning heavy metal ions such as lead and cadmium. The described BiNRs based sensor presents good linear dependence on lead and cadmium ions in the concentration range of 1–50 µg/L for both metal ions with a detection limit of 0.104 µg/L for lead and 0.145 µg/L for cadmium.

Ancillary