Remediation/Treatment Section
Size distribution and filtration property of particles generated from laser ablation decontamination process
Article first published online: 19 JUL 2012
DOI: 10.1002/ep.11679
Copyright © 2012 American Institute of Chemical Engineers (AIChE)
Issue

Environmental Progress & Sustainable Energy
Early View (Online Version of Record published before inclusion in an issue)
Additional Information
How to Cite
Jung, C.-H., Park, H.-S., Won, H.-J., Moon, J.-K., Choi, B.-S. and Choi, W.-K. (2012), Size distribution and filtration property of particles generated from laser ablation decontamination process. Environ. Prog. Sustainable Energy. doi: 10.1002/ep.11679
Publication History
- Article first published online: 19 JUL 2012
- Manuscript Accepted: 23 JUN 2012
- Manuscript Revised: 13 MAY 2012
- Manuscript Received: 5 JAN 2012
Funded by
- National Nuclear Mid-
- Abstract
- Article
- References
- Cited By
Keywords:
- laser ablation decontamination;
- radionuclide;
- particle size distribution;
- collection efficiency;
- air filter
Abstract
This study investigated the size distribution of particles generated from a laser ablation process applied for the decontamination of a hot cell contaminated with radionuclides. To simulate the hot cell contamination conditions, a stainless steel 304 (STS 304) plate on which Co and Cs ions (water soluble radionuclides, WSRs) were deposited and STS 304 specimens coated with Eu2O3 and CeO2 (water insoluble radionuclides, WIRs) were prepared. The particle size distribution and concentration for each contamination condition were then measured. In addition, the filtration characteristics of the particles produced from the laser ablation processes were examined using a high efficiency air (HEPA) filter to completely remove these particles. Under the same laser ablation conditions, the particle concentrations for the water insoluble-contaminated specimen were higher than those for the water soluble-contaminated specimen. The mobility diameter of particles showing the highest concentration ranged from 70 to 80 nm for all tests. For the specimens contaminated with Cs ion, when a potassium salt such as KNO3 or KOH was added, the concentration of particles generated under the same fluence increased owing to a removal in the form of Cs oxide, such as Cs2O. The overall collection efficiency of the tested HEPA filter for the particles generated from the laser ablation was over 99.4% regardless of the type of contaminated specimen. Consequently, it was confirmed that a high efficiency air filter is very effective as a means to capture particles produced from the hot cell decontamination process using laser ablation technique. © 2012 American Institute of Chemical Engineers Environ Prog, 2012

1944-7450/asset/EP_centre.gif?v=1&s=54597eced499e80b69e1920b721512cc914c8eb4)